Analysis on Current Control Strategy of Yunnan-Guizhou Interconnection Project

Yunnan-Guizhou Interconnection Project is the first ± 500 kV DC project in the world.By constructing the transmission channel from Luquan converter station in Yunnan, Gaopo converter station in Guizhou and Zhaoqing converter station in Guangdong, The flexible power transmission between Yunnan, Guizhou and Guangdong has been realized.Correspondingly, the function of its control and protection system also meets the requirements of power transmission under different working conditions of three-terminal operation. The control system realizes the angle control by adjusting the current reference value, and then realizes the power control.Therefore, the determination of the current reference value is one of the core functions of the control system. According to the actual situation of DC three-terminal operation, this paper combs the current control logic, that is, the transformation process of current reference value, with reference to the control software.Describe which functions affect the current reference and how.

Authors

Publication Details

Published
2024-10-19
DOI
https://doi.org/10.1109/dcts62535.2024.10941432
Primary Topic
Civil and Geotechnical Engineering Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis on Current Control Strategy of Yunnan-Guizhou Interconnection Project

Qiudan Shen, Zicong Zhang, Shiwei Zhao
Civil and Geotechnical Engineering Research
article

Analysis on Current Control Strategy of Yunnan-Guizhou Interconnection Project

Qiudan Shen, Zicong Zhang, Shiwei Zhao
article en

Abstract

Yunnan-Guizhou Interconnection Project is the first ± 500 kV DC project in the world.By constructing the transmission channel from Luquan converter station in Yunnan, Gaopo converter station in Guizhou and Zhaoqing converter station in Guangdong, The flexible power transmission between Yunnan, Guizhou and Guangdong has been realized.Correspondingly, the function of its control and protection system also meets the requirements of power transmission under different working conditions of three-terminal operation. The control system realizes the angle control by adjusting the current reference value, and then realizes the power control.Therefore, the determination of the current reference value is one of the core functions of the control system. According to the actual situation of DC three-terminal operation, this paper combs the current control logic, that is, the transformation process of current reference value, with reference to the control software.Describe which functions affect the current reference and how.

Openalex Percentile: Top 48%
Civil and Geotechnical Engineering Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.