Seismic performance analysis of DC transmission tower-line system of unequal height

To explore the influence of unequal leg length combinations on the seismic performance of DC transmission towers, transmission tower models with different leg heights were established for seismic response analysis, Based on incremental dynamic analysis (IDA) method and the failure determination criteria, the dynamic stability performance of unequal tower-wire system under seismic action for $0,3,6$, and 9 m height difference was analyzed. Results indicate that the design of long and short legs makes the vibration mode of transmission tower change, and the joint of short leg and tower body with main material stress increase. The vibration phenomenon of shifting the equilibrium position occurs in the near unstable state, the impact of the unbalanced tension in the conductor of the key components damage aggravated leading to instability damage. Finally, As the height gap increases, the modal effect manifests the stress increase is particularly clear, the unequal tower leg design in the direction of the conductor should be avoided as much as possible in the construction of the project.

Authors

Institutions

Publication Details

Published
2024-10-19
DOI
https://doi.org/10.1109/dcts62535.2024.10941324
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic performance analysis of DC transmission tower-line system of unequal height

Yan Zha, Wulue Zheng, Guang‐Biao Zhou, Xin Zhang et al.
HVDC Systems and Fault Protection
article

Seismic performance analysis of DC transmission tower-line system of unequal height

Yan Zha, Wulue Zheng, Guang‐Biao Zhou, Xin Zhang, Yukang Han
article en

Abstract

To explore the influence of unequal leg length combinations on the seismic performance of DC transmission towers, transmission tower models with different leg heights were established for seismic response analysis, Based on incremental dynamic analysis (IDA) method and the failure determination criteria, the dynamic stability performance of unequal tower-wire system under seismic action for $0,3,6$, and 9 m height difference was analyzed. Results indicate that the design of long and short legs makes the vibration mode of transmission tower change, and the joint of short leg and tower body with main material stress increase. The vibration phenomenon of shifting the equilibrium position occurs in the near unstable state, the impact of the unbalanced tension in the conductor of the key components damage aggravated leading to instability damage. Finally, As the height gap increases, the modal effect manifests the stress increase is particularly clear, the unequal tower leg design in the direction of the conductor should be avoided as much as possible in the construction of the project.

China Three Gorges University (CN), China Southern Power Grid (China) (CN)
Sustainable cities and communities
Openalex Percentile: Top 73%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.