Development and Finite Element Analysis of a Patient-Specific Implant for Atlantoaxial Joint Stabilization via Dorsal Approach in Dogs

To develop a patient-specific implant designed for dorsal access instrumentation, which also serves as a guide for screw insertion, for use in dogs with atlantoaxial instability. The implant must demonstrate no failure in finite element analysis.The development of an implant utilizing computational resources based on a computed tomography scan of a patient with atlantoaxial instability. The final implant model was analysed using finite element methods in flexion, extension, lateral flexion, and torsion to evaluate stress distribution and displacement.A patient-specific implant for dorsal instrumentation was developed, featuring six holes for the insertion of 1.7-mm bicortical locking screws, including two transarticular screws and two additional screws per vertebra. The implant demonstrated a maximum stress point of 425 MPa, well below the material yield strength of 880 MPa, with a maximum displacement of only 0.13 mm.The proposed implant shows promise as it can function as a drilling guide, potentially enhancing safety during instrumentation. Using safe corridors may improve the rigidity of the construct. The implant model did not exhibit any failure when subjected to finite element analysis according to the established criteria.

Authors

Institutions

Publication Details

Journal
Veterinary and Comparative Orthopaedics and Traumatology
Published
2025-04-02
DOI
https://doi.org/10.1055/a-2551-3374
Primary Topic
Veterinary Orthopedics and Neurology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Finite Element Analysis of a Patient-Specific Implant for Atlantoaxial Joint Stabilization via Dorsal Approach in Dogs

Thales Bregadioli, Gabriel Antonio Covino Diamante, Adan Peres Cabreira, Mônica Vicky Bahr Árias
Veterinary and Comparative Orthopaedics and Traumatology
Veterinary Orthopedics and Neurology
article

Development and Finite Element Analysis of a Patient-Specific Implant for Atlantoaxial Joint Stabilization via Dorsal Approach in Dogs

Thales Bregadioli, Gabriel Antonio Covino Diamante, Adan Peres Cabreira, Mônica Vicky Bahr Árias
article en

Abstract

To develop a patient-specific implant designed for dorsal access instrumentation, which also serves as a guide for screw insertion, for use in dogs with atlantoaxial instability. The implant must demonstrate no failure in finite element analysis.The development of an implant utilizing computational resources based on a computed tomography scan of a patient with atlantoaxial instability. The final implant model was analysed using finite element methods in flexion, extension, lateral flexion, and torsion to evaluate stress distribution and displacement.A patient-specific implant for dorsal instrumentation was developed, featuring six holes for the insertion of 1.7-mm bicortical locking screws, including two transarticular screws and two additional screws per vertebra. The implant demonstrated a maximum stress point of 425 MPa, well below the material yield strength of 880 MPa, with a maximum displacement of only 0.13 mm.The proposed implant shows promise as it can function as a drilling guide, potentially enhancing safety during instrumentation. Using safe corridors may improve the rigidity of the construct. The implant model did not exhibit any failure when subjected to finite element analysis according to the established criteria.

Veterinary and Comparative Orthopaedics and TraumatologyVol. 39(01)
Universidade Estadual de Londrina (BR)
Openalex Percentile: Top 93%
Veterinary Orthopedics and Neurology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and Finite Element Analysis of a Patient-Specific Implant for Atlantoaxial Joint Stabilization via Dorsal Approach in Dogs — Thales Bregadioli, Gabriel Antonio Covino Diamante, et al. · Veterinary and Comparative Orthopaedics and Traumatology (2025) | TGRS Research Map | TGRS