Various optimization algorithms for efficient placement and sizing of photovoltaic distributed generations in different networks

Recent research has concentrated on emphasizing the significance of incorporating renewable distributed generations (RDGs), like photovoltaic (PV) and wind turbines (WTs), into the distribution system to address issues related to distributed generation (DG) allocation. The key implications of integrating RDGs include the improvement of voltage profiles and the minimization of power losses. Various optimization techniques, namely Salp Swarm Algorithm (SSA), Marine Predictor Algorithm (MPA), Grey Wolf Optimizer (GWO), Improved Grey Wolf Optimizer (IGWO), and Seagull Optimization Algorithm (SOA), have been applied to achieve optimal allocation and sizing of RDGs in radial distributed systems (RDS). The present paper is structured in two phases. In the initial phase, the Loss Sensitivity Factor (LSF) is employed to identify the most suitable nodes for integrating RDGs. In the second phase, within the selected candidate nodes from the first phase, the optimal location and capacity of RDGs are determined. Additionally, a comprehensive comparison of the proposed optimization methods is conducted to select the most effective solutions for the allocation of units of RDGs. The efficacy of the utilized techniques is validated through testing on two distinct networks, namely the IEEE 33 and 69 buses RDS in MATLAB, with attainments compared against other techniques. Moreover, a larger RDS system of 118- bus IEEE system has been considered in order to enhance its power quality indices. Moreover, a real case of study from Egypt of 15 bus has been considered and evaluated with considering the applied techniques. The results show the enhancement of the voltage profile and decreasing the power losses of the tested system with the DG systems with the superiority of the MPA and SSA algorithms.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-04-02
DOI
https://doi.org/10.1371/journal.pone.0319422
Citations
9
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
6.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Various optimization algorithms for efficient placement and sizing of photovoltaic distributed generations in different networks

Hamdy M. Sultan, Fayza S. Mahmoud, Omar Makram Kamel, Mohamed A. Ismeil et al.
9 citations
PLoS ONE
Optimal Power Flow Distribution
6.57
article

Various optimization algorithms for efficient placement and sizing of photovoltaic distributed generations in different networks

Hamdy M. Sultan, Fayza S. Mahmoud, Omar Makram Kamel, Mohamed A. Ismeil, Ahmed A. Zaki Diab, Abou‐Hashema M. El‐Sayed
article en
9 citations

Abstract

Recent research has concentrated on emphasizing the significance of incorporating renewable distributed generations (RDGs), like photovoltaic (PV) and wind turbines (WTs), into the distribution system to address issues related to distributed generation (DG) allocation. The key implications of integrating RDGs include the improvement of voltage profiles and the minimization of power losses. Various optimization techniques, namely Salp Swarm Algorithm (SSA), Marine Predictor Algorithm (MPA), Grey Wolf Optimizer (GWO), Improved Grey Wolf Optimizer (IGWO), and Seagull Optimization Algorithm (SOA), have been applied to achieve optimal allocation and sizing of RDGs in radial distributed systems (RDS). The present paper is structured in two phases. In the initial phase, the Loss Sensitivity Factor (LSF) is employed to identify the most suitable nodes for integrating RDGs. In the second phase, within the selected candidate nodes from the first phase, the optimal location and capacity of RDGs are determined. Additionally, a comprehensive comparison of the proposed optimization methods is conducted to select the most effective solutions for the allocation of units of RDGs. The efficacy of the utilized techniques is validated through testing on two distinct networks, namely the IEEE 33 and 69 buses RDS in MATLAB, with attainments compared against other techniques. Moreover, a larger RDS system of 118- bus IEEE system has been considered in order to enhance its power quality indices. Moreover, a real case of study from Egypt of 15 bus has been considered and evaluated with considering the applied techniques. The results show the enhancement of the voltage profile and decreasing the power losses of the tested system with the DG systems with the superiority of the MPA and SSA algorithms.

PLoS ONEVol. 20(4)
Minia University Hospital (EG), King Khalid University (SA), Minia University (EG)
Affordable and clean energy
Openalex Percentile: Top 3%
Optimal Power Flow Distribution
6.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.