Effectiveness of aperiodic retinal stimulation in improving temporal visual cortical response

<i>Objective.</i>Visual prostheses can provide partial visual function in patients with retinal degenerative diseases. However, in clinical trials, patients implanted with retinal prostheses have reported perceptual fading, which is thought to be related to response desensitization. Additionally, natural stimuli consist of aperiodic events across a short temporal span, whereas periodic stimulation (fixed inter-pulse intervals (IPIs)) is the standard approach in retinal prosthesis research. In this study, we investigated how aperiodic stimulation of the epiretinal surface affects electrically evoked responses in the primary visual cortex (V1) compared with periodic stimulation.<i>Approach. In vivo</i>experiments were conducted in healthy and retinal-degenerated rats. Periodic stimulation consisted of constant IPIs, whereas aperiodic stimulation was provided by mixed IPIs. We calculated the spike time tiling coefficient to assess response consistency across trials, the significant response ratio, and the spike rate to analyze response desensitization.<i>Main results.</i>The results showed a significantly lower consistency of cortical responses in retinal degenerated rats than in healthy rats at 5 Hz. The consistency of the response to periodic stimulation decreased considerably as the frequency was increased to 10 Hz and 20 Hz in both groups and was greatly improved by applying aperiodic stimulation. In addition, aperiodic stimulation evoked a significantly higher spike rate in response to continuous stimulation at high frequencies (e.g. 10 and 20 Hz).<i>Significance</i>. By applying electrical stimulation with varying IPIs directly on the epiretinal surface, we observed promising results in terms of enhancing cortical response consistency and reducing desensitization. This finding presents a potential approach to enhance the effectiveness of retinal prostheses.

Authors

Institutions

Publication Details

Journal
Journal of Neural Engineering
Published
2025-04-02
DOI
https://doi.org/10.1088/1741-2552/adc83c
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effectiveness of aperiodic retinal stimulation in improving temporal visual cortical response

Leanne Lai-Hang Chan, Zixin Ye
Journal of Neural Engineering
Neuroscience and Neural Engineering
article

Effectiveness of aperiodic retinal stimulation in improving temporal visual cortical response

Leanne Lai-Hang Chan, Zixin Ye
article en

Abstract

<i>Objective.</i>Visual prostheses can provide partial visual function in patients with retinal degenerative diseases. However, in clinical trials, patients implanted with retinal prostheses have reported perceptual fading, which is thought to be related to response desensitization. Additionally, natural stimuli consist of aperiodic events across a short temporal span, whereas periodic stimulation (fixed inter-pulse intervals (IPIs)) is the standard approach in retinal prosthesis research. In this study, we investigated how aperiodic stimulation of the epiretinal surface affects electrically evoked responses in the primary visual cortex (V1) compared with periodic stimulation.<i>Approach. In vivo</i>experiments were conducted in healthy and retinal-degenerated rats. Periodic stimulation consisted of constant IPIs, whereas aperiodic stimulation was provided by mixed IPIs. We calculated the spike time tiling coefficient to assess response consistency across trials, the significant response ratio, and the spike rate to analyze response desensitization.<i>Main results.</i>The results showed a significantly lower consistency of cortical responses in retinal degenerated rats than in healthy rats at 5 Hz. The consistency of the response to periodic stimulation decreased considerably as the frequency was increased to 10 Hz and 20 Hz in both groups and was greatly improved by applying aperiodic stimulation. In addition, aperiodic stimulation evoked a significantly higher spike rate in response to continuous stimulation at high frequencies (e.g. 10 and 20 Hz).<i>Significance</i>. By applying electrical stimulation with varying IPIs directly on the epiretinal surface, we observed promising results in terms of enhancing cortical response consistency and reducing desensitization. This finding presents a potential approach to enhance the effectiveness of retinal prostheses.

Journal of Neural EngineeringVol. 22(2)
City University of Hong Kong (HK)
Good health and well-being
Openalex Percentile: Top 92%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.