Clinicians’ Agreement on Extrapulmonary Radiographic Findings in Chest X-Rays Using a Diagnostic Labelling Scheme

<b>Objective:</b> Reliable reading and annotation of chest X-ray (CXR) images are essential for both clinical decision-making and AI model development. While most of the literature emphasizes pulmonary findings, this study evaluates the consistency and reliability of annotations for extrapulmonary findings, using a labelling scheme. <b>Methods:</b> Six clinicians with varying experience levels (novice, intermediate, and experienced) annotated 100 CXR images using a diagnostic labelling scheme, in two rounds, separated by a three-week washout period. Annotation consistency was assessed using Randolph's free-marginal kappa (RK), prevalence- and bias-adjusted kappa (PABAK), proportion positive agreement (PPA), and proportion negative agreement (PNA). Pairwise comparisons and the McNemar's test were conducted to assess inter-reader and intra-reader agreement. <b>Results:</b> PABAK values indicated high overall grouped labelling agreement (novice: 0.86, intermediate: 0.90, experienced: 0.91). PNA values demonstrated strong agreement on negative findings, while PPA values showed moderate-to-low consistency in positive findings. Significant differences in specific agreement emerged between novice and experienced clinicians for eight labels, but there were no significant variations in RK across experience levels. The McNemar's test confirmed annotation stability between rounds. <b>Conclusions:</b> This study demonstrates that clinician annotations of extrapulmonary findings in CXR are consistent and reliable across different experience levels using a pre-defined diagnostic labelling scheme. These insights aid in optimizing training strategies for both clinicians and AI models.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-04-01
DOI
https://doi.org/10.3390/diagnostics15070902
Primary Topic
Radiology practices and education
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinicians’ Agreement on Extrapulmonary Radiographic Findings in Chest X-Rays Using a Diagnostic Labelling Scheme

Silvia Ingala, Michael Bachmann Nielsen, Jonathan Frederik Carlsen, Dorte Marianne Rohde Stærk et al.
Diagnostics
Radiology practices and education
article

Clinicians’ Agreement on Extrapulmonary Radiographic Findings in Chest X-Rays Using a Diagnostic Labelling Scheme

Silvia Ingala, Michael Bachmann Nielsen, Jonathan Frederik Carlsen, Dorte Marianne Rohde Stærk, Henrik Steglich‐Arnholm, Rasmus Bonnevie, Marco Fraccaro, Alexander Malcolm Rykkje, Lea Marie Pehrson, Tobias Thostrup Andersen, Sune Darkner, Alyas Mayar, Dana Li, P.J. Sørensen, Lotte Borgwardt
article en

Abstract

<b>Objective:</b> Reliable reading and annotation of chest X-ray (CXR) images are essential for both clinical decision-making and AI model development. While most of the literature emphasizes pulmonary findings, this study evaluates the consistency and reliability of annotations for extrapulmonary findings, using a labelling scheme. <b>Methods:</b> Six clinicians with varying experience levels (novice, intermediate, and experienced) annotated 100 CXR images using a diagnostic labelling scheme, in two rounds, separated by a three-week washout period. Annotation consistency was assessed using Randolph's free-marginal kappa (RK), prevalence- and bias-adjusted kappa (PABAK), proportion positive agreement (PPA), and proportion negative agreement (PNA). Pairwise comparisons and the McNemar's test were conducted to assess inter-reader and intra-reader agreement. <b>Results:</b> PABAK values indicated high overall grouped labelling agreement (novice: 0.86, intermediate: 0.90, experienced: 0.91). PNA values demonstrated strong agreement on negative findings, while PPA values showed moderate-to-low consistency in positive findings. Significant differences in specific agreement emerged between novice and experienced clinicians for eight labels, but there were no significant variations in RK across experience levels. The McNemar's test confirmed annotation stability between rounds. <b>Conclusions:</b> This study demonstrates that clinician annotations of extrapulmonary findings in CXR are consistent and reliable across different experience levels using a pre-defined diagnostic labelling scheme. These insights aid in optimizing training strategies for both clinicians and AI models.

DiagnosticsVol. 15(7)
University of Copenhagen (DK), Copenhagen University Hospital (DK), Gentofte Hospital (DK), Rigshospitalet (DK)
Innovationsfonden
Peace, Justice and strong institutions
Openalex Percentile: Top 90%
Radiology practices and education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.