An Evaluation of the Effect of the Guide Socket on the Primary Stability of the Miniscrew in a Polyurethane Cortical Bone Model

Only a few studies in the literature have evaluated the effect of pilot drilling to create a guide socket on the primary stability of miniscrews. The aim of this study was to evaluate the effect of creating a guide socket during miniscrew insertion on the primary stability of the miniscrew in an in vitro polyurethane (PU) cortical bone model. PU blocks with a density of 0.96 g/cm<sup>3</sup> were used for in vitro cortical bone modelling, and 1.8 × 8 mm self-drilling mushroom-head titanium miniscrews were used. A 1 mm diameter surgical fissure drill was used to create the guide sockets in the study groups. A total of 45 miniscrews were included in this study in the no-guide, 2 mm guide, and 4 mm guide groups. The insertion torque values for the miniscrews in the 4 mm guide socket group were significantly lower than in the other groups, and the removal torque values for the miniscrews in the 2 mm guide socket group were significantly higher than in the other groups (<i>p</i> < 0.01). This study demonstrated that a 0.96 g/cm<sup>3</sup> PU block can be used for in vitro cortical bone modelling and that the creation of a 2 mm guide socket increases the primary stability of the 1.8 × 8 mm mushroom-head miniscrew.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2025-04-01
DOI
https://doi.org/10.3390/polym17070962
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Evaluation of the Effect of the Guide Socket on the Primary Stability of the Miniscrew in a Polyurethane Cortical Bone Model

Levent Ciğerim, Nazlı Hilal Kahraman
Polymers
Orthodontics and Dentofacial Orthopedics
article

An Evaluation of the Effect of the Guide Socket on the Primary Stability of the Miniscrew in a Polyurethane Cortical Bone Model

Levent Ciğerim, Nazlı Hilal Kahraman
article en

Abstract

Only a few studies in the literature have evaluated the effect of pilot drilling to create a guide socket on the primary stability of miniscrews. The aim of this study was to evaluate the effect of creating a guide socket during miniscrew insertion on the primary stability of the miniscrew in an in vitro polyurethane (PU) cortical bone model. PU blocks with a density of 0.96 g/cm<sup>3</sup> were used for in vitro cortical bone modelling, and 1.8 × 8 mm self-drilling mushroom-head titanium miniscrews were used. A 1 mm diameter surgical fissure drill was used to create the guide sockets in the study groups. A total of 45 miniscrews were included in this study in the no-guide, 2 mm guide, and 4 mm guide groups. The insertion torque values for the miniscrews in the 4 mm guide socket group were significantly lower than in the other groups, and the removal torque values for the miniscrews in the 2 mm guide socket group were significantly higher than in the other groups (<i>p</i> < 0.01). This study demonstrated that a 0.96 g/cm<sup>3</sup> PU block can be used for in vitro cortical bone modelling and that the creation of a 2 mm guide socket increases the primary stability of the 1.8 × 8 mm mushroom-head miniscrew.

PolymersVol. 17(7)
Van Yüzüncü Yıl Üniversitesi (TR)
Openalex Percentile: Top 93%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.