Numerical accuracy of closed-loop steady state in a zero-dimensional cardiovascular model

Closed-loop cardiovascular models are becoming vital tools in clinical settings, making their accuracy and reliability paramount. While these models rely heavily on steady-state simulations, accuracy because of steady-state convergence is often assumed negligible. Using a reduced-order cardiovascular model created with the CircAdapt framework as a case study, we investigated steady-state convergence behaviour across various integration methods and simulation protocols. To minimize the effect of numerical errors, we first quantified the numerical errors originating from integration methods and model assumptions. We subsequently investigate this steady-state convergence error under two distinct conditions: first without, and then with homeostatic pressure-flow control (PFC), providing a comprehensive assessment of the CircAdapt framework's numerical stability and accuracy. Our results demonstrated that achieving a clinically accurate steady state required 7-15 heartbeats in simulations without regulatory mechanisms. When homeostatic control mechanisms were included to regulate mean arterial pressure and blood volume, more than twice the number of heartbeats was needed. By simulating a variable number of heartbeats tailored to each simulation's characteristics, an efficient balance between computational cost and steady-state accuracy can be achieved. Understanding this balance is crucial as cardiovascular models progress towards clinical use.This article is part of the theme issue 'Uncertainty quantification for healthcare and biological systems (Part 2)'.

Authors

Institutions

Publication Details

Journal
Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences
Published
2025-04-02
DOI
https://doi.org/10.1098/rsta.2024.0208
Citations
4
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
5.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical accuracy of closed-loop steady state in a zero-dimensional cardiovascular model

Nick van Osta, Theo Arts, Joost Lumens, Tammo Delhaas et al.
4 citations
Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences
Cardiovascular Function and Risk Factors
5.55
article

Numerical accuracy of closed-loop steady state in a zero-dimensional cardiovascular model

Nick van Osta, Theo Arts, Joost Lumens, Tammo Delhaas, Tim van Loon, Gitte van den Acker
article en
4 citations

Abstract

Closed-loop cardiovascular models are becoming vital tools in clinical settings, making their accuracy and reliability paramount. While these models rely heavily on steady-state simulations, accuracy because of steady-state convergence is often assumed negligible. Using a reduced-order cardiovascular model created with the CircAdapt framework as a case study, we investigated steady-state convergence behaviour across various integration methods and simulation protocols. To minimize the effect of numerical errors, we first quantified the numerical errors originating from integration methods and model assumptions. We subsequently investigate this steady-state convergence error under two distinct conditions: first without, and then with homeostatic pressure-flow control (PFC), providing a comprehensive assessment of the CircAdapt framework's numerical stability and accuracy. Our results demonstrated that achieving a clinically accurate steady state required 7-15 heartbeats in simulations without regulatory mechanisms. When homeostatic control mechanisms were included to regulate mean arterial pressure and blood volume, more than twice the number of heartbeats was needed. By simulating a variable number of heartbeats tailored to each simulation's characteristics, an efficient balance between computational cost and steady-state accuracy can be achieved. Understanding this balance is crucial as cardiovascular models progress towards clinical use.This article is part of the theme issue 'Uncertainty quantification for healthcare and biological systems (Part 2)'.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering SciencesVol. 383(2293)
Maastricht University (NL), Cardiovascular Research Center (BR)
Good health and well-being
Openalex Percentile: Top 4%
Cardiovascular Function and Risk Factors
5.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.