Clinical evaluation, validation and stability testing of a developed paper-based blood grouping diagnostic test device

Blood transfusion necessitates an obligatory test to examine donor-recipient compatibility. Regardless of the typical traditional methods, new blood typing approaches are considered for uncomplicated, correct, and precise testing. In this study, we evaluated the rapid and affordable point-of-care blood typing device and explored new approaches to increase its stability/shelf life. A total of 729 blood samples were validated using this paper-based device. Medical students/staff (total 260) of MNR Medical College & Hospital, Telangana, India, and 57 volunteers from India MedTech Expo 2023 and G20 3rd Health Working Group Meeting organized by Govt. of India, were considered for on-spot testing. The participants were asked to sign the consent form and enter their blood groups, which were later used for confirmation and validation. Out of 260 medical students/staff, this blood typing paper device successfully validated blood groups of 204 samples and tested 45 unknown blood groups. It also provided corrected blood groups to 11, thus having a sensitivity of 100 %. The device tested on MedTech Expo and G20 Health Meeting volunteers showed 100 % specificity. Around 400 blood samples collected from the hospital were tested with the paper device and compared simultaneously with the conventional glass slide method. 12 blood samples were tested via tube method and compared to paper devices. The sensitivity in all cases was superior to that of the traditional method with 100 % specificity. The developed device with a new biofunctionalization strategy exhibited excellent stability for 3 and 6 months at room temperature and 2-8 °C, respectively. This simple and easy diagnostic test device epitomizes a major stride towards enabling comprehensive screening of blood typing both in children and adults. It signifies its feasibility in resource-limited clinical settings towards making a positive diagnosis.

Authors

Institutions

Publication Details

Journal
Clinica Chimica Acta
Published
2025-04-02
DOI
https://doi.org/10.1016/j.cca.2025.120276
Citations
3
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical evaluation, validation and stability testing of a developed paper-based blood grouping diagnostic test device

Shahila Parween, Amit Asthana, Arjun Jayachandran, PC Ram et al.
3 citations
Clinica Chimica Acta
Biosensors and Analytical Detection
2.02
article

Clinical evaluation, validation and stability testing of a developed paper-based blood grouping diagnostic test device

Shahila Parween, Amit Asthana, Arjun Jayachandran, PC Ram, K.V.S. Ratnam, Prajna Arpita, Harsh Vardhan Shrivastava
article en
3 citations

Abstract

Blood transfusion necessitates an obligatory test to examine donor-recipient compatibility. Regardless of the typical traditional methods, new blood typing approaches are considered for uncomplicated, correct, and precise testing. In this study, we evaluated the rapid and affordable point-of-care blood typing device and explored new approaches to increase its stability/shelf life. A total of 729 blood samples were validated using this paper-based device. Medical students/staff (total 260) of MNR Medical College & Hospital, Telangana, India, and 57 volunteers from India MedTech Expo 2023 and G20 3rd Health Working Group Meeting organized by Govt. of India, were considered for on-spot testing. The participants were asked to sign the consent form and enter their blood groups, which were later used for confirmation and validation. Out of 260 medical students/staff, this blood typing paper device successfully validated blood groups of 204 samples and tested 45 unknown blood groups. It also provided corrected blood groups to 11, thus having a sensitivity of 100 %. The device tested on MedTech Expo and G20 Health Meeting volunteers showed 100 % specificity. Around 400 blood samples collected from the hospital were tested with the paper device and compared simultaneously with the conventional glass slide method. 12 blood samples were tested via tube method and compared to paper devices. The sensitivity in all cases was superior to that of the traditional method with 100 % specificity. The developed device with a new biofunctionalization strategy exhibited excellent stability for 3 and 6 months at room temperature and 2-8 °C, respectively. This simple and easy diagnostic test device epitomizes a major stride towards enabling comprehensive screening of blood typing both in children and adults. It signifies its feasibility in resource-limited clinical settings towards making a positive diagnosis.

Clinica Chimica ActaVol. 572
National Institute of Pharmaceutical Education and Research - Ahmedabad (IN), MNR Medical College and Hospital (IN), National Institute of Pharmaceutical Education and Research (IN)
Department of Science and Technology, Ministry of Science and Technology, India, Science and Engineering Research Board
Partnerships for the goals
Openalex Percentile: Top 15%
Biosensors and Analytical Detection
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.