Theoretical Exploration of a Noble Metal-Decorated Black Arsenic–Phosphorus Monolayer as a Highly Sensitive Gas Sensor for Dissolved Gas Detection in Power Transformers

The aging or failure of power transformers poses a significant threat to both production and daily life, and employing characteristic dissolved gas detection offers an effective early warning system to mitigate such risks. In this study, we conducted first-principles simulations to investigate the adsorption and sensing characteristics of two-dimensional intrinsic and noble metal-decorated AsP monolayers toward four characteristic gases (C<sub>2</sub>H<sub>4</sub>, H<sub>2</sub>, C<sub>2</sub>H<sub>2</sub>, and CO). Additionally, we conducted an in-depth analysis of the electronic structure and its impact on the sensing performance within the adsorption systems. The study demonstrates that the introduction of a noble metal improves gas behaviors, with the Ru-decorated AsP monolayer exhibiting particularly superior adsorption and sensing performances. At different temperatures, the H<sub>2</sub>/Ru-AsP adsorption system in transformer oil demonstrates excellent adsorption behavior. During the initial and later stages (from 350 to 900 K) of power transformer failure, the adsorption energy change is approximately -0.8 eV, and its desorption time is less than 0.5 s. Even in scenarios involving severe faults that result in equipment overheating and the subsequent generation of gases such as C<sub>2</sub>H<sub>2</sub> and C<sub>2</sub>H<sub>4</sub>, the sensor demonstrates a consistent response time of less than 0.3 s. This work provides valuable research support for characteristic gas detection in the safe operation of power transformers.

Authors

Institutions

Publication Details

Journal
Langmuir
Published
2025-04-02
DOI
https://doi.org/10.1021/acs.langmuir.4c05197
Citations
3
Primary Topic
2D Materials and Applications
Type
article
Field-Weighted Citation Impact
1.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Theoretical Exploration of a Noble Metal-Decorated Black Arsenic–Phosphorus Monolayer as a Highly Sensitive Gas Sensor for Dissolved Gas Detection in Power Transformers

Xue‐Hai Ju, Xiaolei Li, Tengfei Wang, Junkai Wang et al.
3 citations
Langmuir
2D Materials and Applications
1.55
article

Theoretical Exploration of a Noble Metal-Decorated Black Arsenic–Phosphorus Monolayer as a Highly Sensitive Gas Sensor for Dissolved Gas Detection in Power Transformers

Xue‐Hai Ju, Xiaolei Li, Tengfei Wang, Junkai Wang, Mingzhu Liu
article en
3 citations

Abstract

The aging or failure of power transformers poses a significant threat to both production and daily life, and employing characteristic dissolved gas detection offers an effective early warning system to mitigate such risks. In this study, we conducted first-principles simulations to investigate the adsorption and sensing characteristics of two-dimensional intrinsic and noble metal-decorated AsP monolayers toward four characteristic gases (C<sub>2</sub>H<sub>4</sub>, H<sub>2</sub>, C<sub>2</sub>H<sub>2</sub>, and CO). Additionally, we conducted an in-depth analysis of the electronic structure and its impact on the sensing performance within the adsorption systems. The study demonstrates that the introduction of a noble metal improves gas behaviors, with the Ru-decorated AsP monolayer exhibiting particularly superior adsorption and sensing performances. At different temperatures, the H<sub>2</sub>/Ru-AsP adsorption system in transformer oil demonstrates excellent adsorption behavior. During the initial and later stages (from 350 to 900 K) of power transformer failure, the adsorption energy change is approximately -0.8 eV, and its desorption time is less than 0.5 s. Even in scenarios involving severe faults that result in equipment overheating and the subsequent generation of gases such as C<sub>2</sub>H<sub>2</sub> and C<sub>2</sub>H<sub>4</sub>, the sensor demonstrates a consistent response time of less than 0.3 s. This work provides valuable research support for characteristic gas detection in the safe operation of power transformers.

LangmuirVol. 41(14)
Nanjing University of Science and Technology (CN), Institute of Molecular Functional Materials (CN), Division of Materials Science and Engineering (AU), Henan Polytechnic University (CN)
Henan Polytechnic University, Natural Science Foundation of Henan Province
Openalex Percentile: Top 19%
2D Materials and Applications
1.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.