Study of the Structure and Mechanical Properties of Ti-38Zr-11Nb Alloy

Hip joint implants are among the most prevalent types of medical implants utilized for the replacement of damaged joints. The utilization of modern implant materials, such as cobalt-chromium alloys, stainless steel, titanium, and other titanium alloys, is accompanied by challenges, including the toxicity of certain elements (e.g., aluminum, vanadium, nickel) and excessive Young's modulus, which adversely impact biomechanical compatibility. A mismatch between the stiffness of the implant material and the bone tissue, known as stress shielding, can lead to adverse outcomes such as bone resorption and implant loosening. Recent studies have shifted the focus to β-titanium alloys due to their exceptional biocompatibility, corrosion resistance, and low Young's modulus, which is close to the Young's modulus of bone tissue (10-30 GPa). In this study, the microstructure, mechanical properties, and phase stability of the Ti-38Zr-11Nb alloy were investigated. Energy dispersion spectrometry was employed to confirm the homogeneous distribution of Ti, Zr, and Nb in the alloy. A subsequent microstructural analysis revealed the presence of elongated β-grains subsequent to rolling and quenching. Furthermore, grinding contributed to the process of recrystallization and the formation of subgrains. X-ray diffraction analysis confirmed the presence of a stable β-phase under any heat treatment conditions, which can be explained by the use of Nb as a β-stabilizer and Zr as a neutral element with a weak β-stabilizing effect in the presence of other β-stabilizers. Furthermore, the modulus of elasticity, as determined by tensile testing, exhibited a decline from 85 GPa to 81 GPa after annealing. Mechanical tests demonstrated a substantial enhancement in tensile strength (from 529 MPa to 628 MPa) concurrent with a 32% reduction in elongation to fracture of the samples. These alterations are attributed to microstructural transformations, including the formation of subgrains and the rearrangement of dislocations. This study's findings suggest that the Ti-38Zr-11Nb alloy has potential as a material of choice due to its lower Young's modulus compared to traditional materials and its stable β-phase, which enhances the implant's durability and reduces the risk of brittle phases forming over time. This study demonstrates that the corrosion resistance of titanium grade 2 and Ti-38Zr-11Nb is comparable. The material in question exhibited no evidence of cytotoxic activity in the context of mammalian cells.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2025-04-02
DOI
https://doi.org/10.3390/jfb16040126
Primary Topic
Titanium Alloys Microstructure and Properties
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of the Structure and Mechanical Properties of Ti-38Zr-11Nb Alloy

Ya. A. Morozova, M. E. Prutskov, А. D. Gorbenko, Boris Rumyantsev et al.
Journal of Functional Biomaterials
Titanium Alloys Microstructure and Properties
article

Study of the Structure and Mechanical Properties of Ti-38Zr-11Nb Alloy

Ya. A. Morozova, M. E. Prutskov, А. D. Gorbenko, Boris Rumyantsev, E. O. Nasakina, M A Sudarchikova, E. E. Baranov, М. А. Каплан, K. V. Sergienko, L A Shatova, А. Г. Колмаков, Andrey P. Chizhikov, T. M. Sevostyanova, M. L. Kheifetz, S. V. Konushkin, M. A. Sevostyanov, S. A. Mikhlik, Aleksandr V Simakin, Ilya V. Baimler
article en

Abstract

Hip joint implants are among the most prevalent types of medical implants utilized for the replacement of damaged joints. The utilization of modern implant materials, such as cobalt-chromium alloys, stainless steel, titanium, and other titanium alloys, is accompanied by challenges, including the toxicity of certain elements (e.g., aluminum, vanadium, nickel) and excessive Young's modulus, which adversely impact biomechanical compatibility. A mismatch between the stiffness of the implant material and the bone tissue, known as stress shielding, can lead to adverse outcomes such as bone resorption and implant loosening. Recent studies have shifted the focus to β-titanium alloys due to their exceptional biocompatibility, corrosion resistance, and low Young's modulus, which is close to the Young's modulus of bone tissue (10-30 GPa). In this study, the microstructure, mechanical properties, and phase stability of the Ti-38Zr-11Nb alloy were investigated. Energy dispersion spectrometry was employed to confirm the homogeneous distribution of Ti, Zr, and Nb in the alloy. A subsequent microstructural analysis revealed the presence of elongated β-grains subsequent to rolling and quenching. Furthermore, grinding contributed to the process of recrystallization and the formation of subgrains. X-ray diffraction analysis confirmed the presence of a stable β-phase under any heat treatment conditions, which can be explained by the use of Nb as a β-stabilizer and Zr as a neutral element with a weak β-stabilizing effect in the presence of other β-stabilizers. Furthermore, the modulus of elasticity, as determined by tensile testing, exhibited a decline from 85 GPa to 81 GPa after annealing. Mechanical tests demonstrated a substantial enhancement in tensile strength (from 529 MPa to 628 MPa) concurrent with a 32% reduction in elongation to fracture of the samples. These alterations are attributed to microstructural transformations, including the formation of subgrains and the rearrangement of dislocations. This study's findings suggest that the Ti-38Zr-11Nb alloy has potential as a material of choice due to its lower Young's modulus compared to traditional materials and its stable β-phase, which enhances the implant's durability and reduces the risk of brittle phases forming over time. This study demonstrates that the corrosion resistance of titanium grade 2 and Ti-38Zr-11Nb is comparable. The material in question exhibited no evidence of cytotoxic activity in the context of mammalian cells.

Journal of Functional BiomaterialsVol. 16(4)
Baikov Institute of Metallurgy and Materials Science (RU), Voronezh State Technical University (RU), National Medical and Surgical Center named after N.I. Pirogov (RU), Moscow Regional Scientific Research Clinical Institute. MF Vladimirsky (RU), Ministry of Health of the Russian Federation (RU), Institute of Structural Macrokinetics and Materials Science (RU), Russian Research Institute for Phytopathology (RU), Prokhorov General Physics Institute (RU), Institute of Applied Physics (BY)
Russian Science Foundation
Openalex Percentile: Top 96%
Titanium Alloys Microstructure and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.