Inverter-based resources dominated grid: Voltage and frequency stability in a weakly interconnected power system
• This study investigates the combined effect of high PVand wind power penetration on the system voltage stability and frequency response in a weak interconnected power system. • The case study focuses on the Senegalese transmission network during inverter-based renewable energy-dominated grid. • The required dynamic model of voltage, frequency control and protection scheme at large-scale photovoltaic plants (LSPVPs) are considered. • The impact of retiring fossil plants and replacing them with large-scale photovoltaic plants is explored. • The impact of fault clearing time duration and momentary cessation of reactive power LSPVP on voltage and frequency response are emphasized. As power systems transition toward sustainable generation, the growing integration of inverter-based resources (IBR) poses challenges to secure power system operations, especially in grids with limited capacity. In this study, the large signal stability of the Senegalese transmission network in a condition of inverter-dominated grid is evaluated. Two IBR penetration rate scenarios were investigated: a base case with 57.7 % based on 2021 peak IBR and a second scenario with 66.8 % in DigSILENT PowerFactory. The voltage stability at critical buses and the frequency response of the system were analyzed against the grid code. The system response following a balanced triphase short circuit fault, where the impact of fault-clearing time and reactive power operation mode of PV plants was investigated. The frequency response is assessed following largest power infeed loss by plants technology (IBR or synchronous generator). The results demonstrate that inverter-dominated grid mainly impact frequency stability rather than voltage stability, with the disconnection of weaker PV plants during faults leading to underfrequency load shedding. High IBR penetration primarily resulted in weakening the connection point of the PV electrically distant from conventional power plants during faults. A fault clearing time exceeding the low voltage ride-through of PV plant and the cessation of reactive power injection by PV caused the trip of weaker PV plants. In summary a secure power system operation at 57.7 % and 66.8 % is achievable under the condition that the fault does not result in a generation loss that exceeds 5.2 % of the total dispatched power.
Authors
- Ousmane Manga Adamou (ORCID: https://orcid.org/0000-0002-6794-5928)
- Lamine Thiaw
- Martin Wolter (ORCID: https://orcid.org/0000-0003-0281-0501)
- Ndeye Khady Diop Dieng
Institutions
- Université Abdou Moumouni (NE)
- West African Science Service Centre on Climate Change and Adapted Land Use (GH)
- Otto-von-Guericke-Universität Magdeburg (DE)
- Cheikh Anta Diop University (SN)
Publication Details
- Journal
- e-Prime - Advances in Electrical Engineering Electronics and Energy
- Published
- 2025-04-02
- DOI
- https://doi.org/10.1016/j.prime.2025.100984
- Citations
- 5
- Primary Topic
- Microgrid Control and Optimization
- Type
- article
- Field-Weighted Citation Impact
- 6.07
Funders
- Bundesministerium für Bildung und Forschung
- West African Science Service Centre on Climate Change and Adapted Land Use