Multistage Linear Frequency Scanning Mass Analysis Processed by Fractional Fourier Transform

The common method of mass analysis in a linear ion trap mass spectrometer is to eject ions with different mass-to-charge ratios (<i>m</i>/<i>z</i>) at different times by resonance excitation. Ions are ejected onto an electron multiplier (EM), generating pulsed signals called the ejection signal. Typically, the ejection signal consisting of multiple pulses is smoothed into a wider Gaussian-like pulse due to the limited bandwidth of the electronic system. For different scan rates and different samples, this bandwidth-limited electronic system and signal smoothing process will differentially increase the peak width and thus decrease the mass resolution. In this study, experiments at different scan rates were performed on a "Brick" miniature linear ion trap mass spectrometer. We propose a multistage linear frequency scanning mode that achieves improved mass resolution and extended mass range, in which fractional Fourier transform is applied to process the ejection signals. The proposed signal processing method improves the mass resolution and mitigates the impact of ghost peaks attributed to scattered ion ejection. A peak width of 0.84 Da at a <i>m</i>/<i>z</i> value of 242 and a scan rate of 8000 Da/s was achieved in experiments.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2025-04-01
DOI
https://doi.org/10.1021/jasms.5c00012
Citations
1
Primary Topic
Image and Signal Denoising Methods
Type
article
Field-Weighted Citation Impact
1.28

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multistage Linear Frequency Scanning Mass Analysis Processed by Fractional Fourier Transform

Dayu Li, Lei Hu, Shi Zhang, W. L. Xu et al.
1 citations
Journal of the American Society for Mass Spectrometry
Image and Signal Denoising Methods
1.28
article

Multistage Linear Frequency Scanning Mass Analysis Processed by Fractional Fourier Transform

Dayu Li, Lei Hu, Shi Zhang, W. L. Xu, Haoqiang Yan
article en
1 citations

Abstract

The common method of mass analysis in a linear ion trap mass spectrometer is to eject ions with different mass-to-charge ratios (<i>m</i>/<i>z</i>) at different times by resonance excitation. Ions are ejected onto an electron multiplier (EM), generating pulsed signals called the ejection signal. Typically, the ejection signal consisting of multiple pulses is smoothed into a wider Gaussian-like pulse due to the limited bandwidth of the electronic system. For different scan rates and different samples, this bandwidth-limited electronic system and signal smoothing process will differentially increase the peak width and thus decrease the mass resolution. In this study, experiments at different scan rates were performed on a "Brick" miniature linear ion trap mass spectrometer. We propose a multistage linear frequency scanning mode that achieves improved mass resolution and extended mass range, in which fractional Fourier transform is applied to process the ejection signals. The proposed signal processing method improves the mass resolution and mitigates the impact of ghost peaks attributed to scattered ion ejection. A peak width of 0.84 Da at a <i>m</i>/<i>z</i> value of 242 and a scan rate of 8000 Da/s was achieved in experiments.

Journal of the American Society for Mass SpectrometryVol. 36(5)
Beijing Institute of Technology (CN), Precision Research (United States) (US), Universidad del Noreste (MX)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 22%
Image and Signal Denoising Methods
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Multistage Linear Frequency Scanning Mass Analysis Processed by Fractional Fourier Transform — Dayu Li, Lei Hu, et al. · Journal of the American Society for Mass Spectrometry (2025) | TGRS Research Map | TGRS