A conditional point cloud diffusion model for deformable liver motion tracking via a single arbitrarily-angled x-ray projection

<i>Objective.</i>Deformable liver motion tracking using a single x-ray projection enables real-time motion monitoring and treatment intervention. We introduce a conditional point cloud diffusion (PCD) model-based framework for accurate and robust liver motion tracking from arbitrarily angled single x-ray projections.<i>Approach.</i>We propose a conditional PCD model for liver motion tracking (PCD-Liver), which estimates volumetric liver motion by solving deformable vector fields (DVFs) of a prior liver surface point cloud, based on a single x-ray image. It is a patient-specific model of two main components: a rigid alignment model to estimate the liver's overall shifts, and a conditional PCD model that further corrects for the liver surface's deformation. Conditioned on the motion-encoded features extracted from a single x-ray projection by a geometry-informed feature pooling layer, the diffusion model iteratively solves detailed liver surface DVFs in a projection angle-agnostic fashion. The liver surface motion solved by PCD-Liver is subsequently fed as the boundary condition into a U-Net-based biomechanical model to infer the liver's internal motion to localize liver tumors. A dataset of 10 liver cancer patients was used for evaluation. We used the root mean square error (RMSE) and 95-percentile Hausdorff distance (HD95) metrics to examine the liver point cloud motion estimation accuracy, and the center-of-mass error (COME) to quantify the liver tumor localization error.<i>Main Results.</i>The mean (±s.d.) RMSE, HD95, and COME of the prior liver or tumor before motion estimation were 8.82 mm (±3.58 mm), 10.84 mm (±4.55 mm), and 9.72 mm (±4.34 mm), respectively. After PCD-Liver's motion estimation, the corresponding values were 3.63 mm (±1.88 mm), 4.29 mm (±1.75 mm), and 3.46 mm (±2.15 mm). Under highly noisy conditions, PCD-Liver maintained stable performance.<i>Significance.</i>This study presents an accurate and robust framework for liver deformable motion estimation and tumor localization for image-guided radiotherapy.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-05-30
DOI
https://doi.org/10.1088/1361-6560/addf0e
Citations
1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A conditional point cloud diffusion model for deformable liver motion tracking via a single arbitrarily-angled x-ray projection

Chenyang Shen, Jing Wang, You Zhang, Yunxiang Li et al.
1 citations
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
1.88
article

A conditional point cloud diffusion model for deformable liver motion tracking via a single arbitrarily-angled x-ray projection

Chenyang Shen, Jing Wang, You Zhang, Yunxiang Li, Shunyu Yan, Hua‐Chieh Shao, Jiacheng Xie
article en
1 citations

Abstract

<i>Objective.</i>Deformable liver motion tracking using a single x-ray projection enables real-time motion monitoring and treatment intervention. We introduce a conditional point cloud diffusion (PCD) model-based framework for accurate and robust liver motion tracking from arbitrarily angled single x-ray projections.<i>Approach.</i>We propose a conditional PCD model for liver motion tracking (PCD-Liver), which estimates volumetric liver motion by solving deformable vector fields (DVFs) of a prior liver surface point cloud, based on a single x-ray image. It is a patient-specific model of two main components: a rigid alignment model to estimate the liver's overall shifts, and a conditional PCD model that further corrects for the liver surface's deformation. Conditioned on the motion-encoded features extracted from a single x-ray projection by a geometry-informed feature pooling layer, the diffusion model iteratively solves detailed liver surface DVFs in a projection angle-agnostic fashion. The liver surface motion solved by PCD-Liver is subsequently fed as the boundary condition into a U-Net-based biomechanical model to infer the liver's internal motion to localize liver tumors. A dataset of 10 liver cancer patients was used for evaluation. We used the root mean square error (RMSE) and 95-percentile Hausdorff distance (HD95) metrics to examine the liver point cloud motion estimation accuracy, and the center-of-mass error (COME) to quantify the liver tumor localization error.<i>Main Results.</i>The mean (±s.d.) RMSE, HD95, and COME of the prior liver or tumor before motion estimation were 8.82 mm (±3.58 mm), 10.84 mm (±4.55 mm), and 9.72 mm (±4.34 mm), respectively. After PCD-Liver's motion estimation, the corresponding values were 3.63 mm (±1.88 mm), 4.29 mm (±1.75 mm), and 3.46 mm (±2.15 mm). Under highly noisy conditions, PCD-Liver maintained stable performance.<i>Significance.</i>This study presents an accurate and robust framework for liver deformable motion estimation and tumor localization for image-guided radiotherapy.

Physics in Medicine and BiologyVol. 70(12)
Southwestern Medical Center (US), Advanced Imaging Research (United States) (US), Artificial Intelligence in Medicine (Canada) (CA), Southwestern Medical Center (US), The University of Texas Southwestern Medical Center (US)
Varian Medical Systems, National Institutes of Health
Good health and well-being
Openalex Percentile: Top 19%
Advanced Radiotherapy Techniques
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies