High-temperature partial discharge characteristics of power module packaging insulation under square pulses based on multispectral optical detection method

The power module package insulation is prone to partial discharge (PD) under fast square pulses, which is one of the main reasons for power module packaging failure. However, there are few studies on PD under square electrothermal coupling stress. One of the important reasons is that the electromagnetic interference and displacement current generated by the rising and falling edges of the square pulse seriously interfere with the detection of PD. To address this problem, this paper proposes a multi-spectral optical detection method with high sensitivity and strong anti-interference. Based on the multi-spectral synchronous detection platform, the high-temperature PD characteristics of power module package insulation under square pulses are studied. The results show that the partial discharge inception voltage (PDIV) decreases with increasing temperature, and the intensity of the PD multi-spectral signal increases with increasing temperature. In addition, the statistical analysis of the maximum optical signal intensity, cumulative optical signal intensity, number of PDs, and phase of PD under square pulse shows that with the increase of temperature, the maximum optical signal intensity and cumulative optical signal intensity of PD increase, and PD events mostly occur on both sides of the square pulse. Among them, the optical signal in the near-ultraviolet band is dominant, and the near-infrared signal has an obvious increase trend. These findings are of great significance for the reliability detection of power module package insulation.

Authors

Institutions

Publication Details

Journal
Frontiers in Energy Research
Published
2025-04-02
DOI
https://doi.org/10.3389/fenrg.2025.1580823
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-temperature partial discharge characteristics of power module packaging insulation under square pulses based on multispectral optical detection method

Qi Ni, Yi Ding, Meng Sun, Biao Wang et al.
Frontiers in Energy Research
High voltage insulation and dielectric phenomena
article

High-temperature partial discharge characteristics of power module packaging insulation under square pulses based on multispectral optical detection method

Qi Ni, Yi Ding, Meng Sun, Biao Wang, Heng Qian
article en

Abstract

The power module package insulation is prone to partial discharge (PD) under fast square pulses, which is one of the main reasons for power module packaging failure. However, there are few studies on PD under square electrothermal coupling stress. One of the important reasons is that the electromagnetic interference and displacement current generated by the rising and falling edges of the square pulse seriously interfere with the detection of PD. To address this problem, this paper proposes a multi-spectral optical detection method with high sensitivity and strong anti-interference. Based on the multi-spectral synchronous detection platform, the high-temperature PD characteristics of power module package insulation under square pulses are studied. The results show that the partial discharge inception voltage (PDIV) decreases with increasing temperature, and the intensity of the PD multi-spectral signal increases with increasing temperature. In addition, the statistical analysis of the maximum optical signal intensity, cumulative optical signal intensity, number of PDs, and phase of PD under square pulse shows that with the increase of temperature, the maximum optical signal intensity and cumulative optical signal intensity of PD increase, and PD events mostly occur on both sides of the square pulse. Among them, the optical signal in the near-ultraviolet band is dominant, and the near-infrared signal has an obvious increase trend. These findings are of great significance for the reliability detection of power module package insulation.

Frontiers in Energy ResearchVol. 13
Shanghai Jiao Tong University (CN)
State Grid Corporation of China
Openalex Percentile: Top 96%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-temperature partial discharge characteristics of power module packaging insulation under square pulses based on multispectral optical detection method — Qi Ni, Yi Ding, et al. · Frontiers in Energy Research (2025) | TGRS Research Map | TGRS