The ultra-low material budget GEM-based TPC for tracking with VMM3a readout

Abstract The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in different facilities to study its tracking performance. The most attractive feature of this detector is its ultra-low material budget, which is 0.28% X/X 0 and can be further reduced by decreasing the thickness of the gas traversed by the incident particles. Thus, it provides excellent position reconstruction and reduced multi-scattering. This detector consists of two GEM-TPCs with drift fields in opposite directions, achieved by rotating one 180 degrees in the middle plane with respect to the other. These two GEM-TPCs share the same gas volume, i.e., inside a single vessel. This configuration is called a TWIN configuration. The results presented in this work were measured using the newly integrated VMM3a-SRS readout electronics, an important milestone in improving overall performance and capabilities. In 2024, this detector was tested at the H4 beamline of the SPS at CERN, using muons and pions and with different gas mixtures like, for instance: Ar/CO 2 (70/30 %), He/CO 2 (70/30 %) and He/CO 2 (90/10 %). The helium-based mixtures were used to commission the detector to track low momenta muons required in the PSI muon-induced X-ray emission (MIXE) experiment. The results obtained from these measurements, a brief discussion of the methodology used for the data analysis, and a comparison of the spatial resolution for different gas mixtures will be presented.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-04-01
DOI
https://doi.org/10.1088/1748-0221/20/04/c04004
Citations
1
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
1.87
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The ultra-low material budget GEM-based TPC for tracking with VMM3a readout

H. Muller, F. Brunbauer, D. Janssens, Thomas Prokscha et al.
1 citations
Journal of Instrumentation
Particle Detector Development and Performance
1.87
article

The ultra-low material budget GEM-based TPC for tracking with VMM3a readout

H. Muller, F. Brunbauer, D. Janssens, Thomas Prokscha, Gianluca Janka, M. W. Heiss, L. Scharenberg, G. Orlandini, B. Banto Oberhauser, K.J. Flöthner, L. Ropelewski, R. Veenhof, Michael Meurer, S. Biswas, M. Lisowska, J. Samarati, A. Amato, F. Sauli, D. Pfeiffer, M. van Stenis, Xiaojian Zhao, F. García, E. Oliveri, B. Zeh
article en
1 citations

Abstract

Abstract The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in different facilities to study its tracking performance. The most attractive feature of this detector is its ultra-low material budget, which is 0.28% X/X 0 and can be further reduced by decreasing the thickness of the gas traversed by the incident particles. Thus, it provides excellent position reconstruction and reduced multi-scattering. This detector consists of two GEM-TPCs with drift fields in opposite directions, achieved by rotating one 180 degrees in the middle plane with respect to the other. These two GEM-TPCs share the same gas volume, i.e., inside a single vessel. This configuration is called a TWIN configuration. The results presented in this work were measured using the newly integrated VMM3a-SRS readout electronics, an important milestone in improving overall performance and capabilities. In 2024, this detector was tested at the H4 beamline of the SPS at CERN, using muons and pions and with different gas mixtures like, for instance: Ar/CO 2 (70/30 %), He/CO 2 (70/30 %) and He/CO 2 (90/10 %). The helium-based mixtures were used to commission the detector to track low momenta muons required in the PSI muon-induced X-ray emission (MIXE) experiment. The results obtained from these measurements, a brief discussion of the methodology used for the data analysis, and a comparison of the spatial resolution for different gas mixtures will be presented.

Journal of InstrumentationVol. 20(04)
University of Bonn (DE), Université Paris-Saclay (FR), European Spallation Source (SE), Helsinki Institute of Physics (FI), Institute for Biomedical Engineering (CH), European Organization for Nuclear Research (CH), Ludwig-Maximilians-Universität München (DE)
Openalex Percentile: Top 15%
Particle Detector Development and Performance
1.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.