Comparative Study between Treatment Outcomes in using Helical Blade and Telescopic Lag Screw in Proximal Femoral Nail for the Treatment of Unstable Intertrochanteric Fractures

Intertrochanteric fractures are common in the elderly population and present significant challenges due to associated comorbidities. Operative fixation techniques have evolved over the decades, with proximal femoral nailing (PFN) being a preferred method. This study compares the outcomes of PFN using a helical blade versus a telescopic lag screw. Conducted at the Department of Orthopaedics, Jubilee Mission Medical College & Research Institute, Thrissur, Kerala, India for a duration of 18 months from January 2023 to June 2024. A total of 50 patients with intertrochanteric femur fractures were included in the study and divided into two groups: Group A (PFN with helical blade) and Group B (PFN with telescopic lag screw). Patients were assessed based on parameters such as time for union, neck shaft angle, Tip Apex Distance (TAD), Harris Hip Score, and complications. Statistical analysis was performed using SPSS software. Neck Shaft Angle was normal in 72% of Group A and 68% of Group B, with no significant difference, Tip Apex Distance (TAD) was higher in Group A at 4, 12, and 24 weeks follow-up, with statistical significance (p<0.05). Harris Hip Score was significantly higher in Group B at 4 weeks follow-up (p=0.014), but no significant difference at 12 and 24 weeks. 16% of patients in Group A experienced screw cut-out, which was statistically significant. One patient in each group experienced screw back-out. PFN with telescopic lag screw demonstrated superior outcomes compared to PFN with helical blade, particularly in terms of lower Tip Apex Distance, increased complication rates such as screw backout, screw cut out and higher Harris Hip Scores at early follow-up. A high Tip Apex Distance correlates with an increased risk of device cut-out from the femur head. Keywords :Unstable intertrochanteric fractures; Helical blade; Telescopic Lag screw; Tip Apex distance; Harris Hip Score

Authors

Institutions

Publication Details

Journal
THE JOURNAL OF THE BULGARIAN ORTHOPAEDICS AND TRAUMA ASSOCIATION
Published
2025-04-02
DOI
https://doi.org/10.58542/jbota.v62i1.158
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Study between Treatment Outcomes in using Helical Blade and Telescopic Lag Screw in Proximal Femoral Nail for the Treatment of Unstable Intertrochanteric Fractures

Jacob Daniel, D. M., D Philip, Dr Vishal Thomas Oommen et al.
THE JOURNAL OF THE BULGARIAN ORTHOPAEDICS AND TRAUMA ASSOCIATION
Hip and Femur Fractures
article

Comparative Study between Treatment Outcomes in using Helical Blade and Telescopic Lag Screw in Proximal Femoral Nail for the Treatment of Unstable Intertrochanteric Fractures

Jacob Daniel, D. M., D Philip, Dr Vishal Thomas Oommen, Dr Kiran Sreekandan
article en

Abstract

Intertrochanteric fractures are common in the elderly population and present significant challenges due to associated comorbidities. Operative fixation techniques have evolved over the decades, with proximal femoral nailing (PFN) being a preferred method. This study compares the outcomes of PFN using a helical blade versus a telescopic lag screw. Conducted at the Department of Orthopaedics, Jubilee Mission Medical College & Research Institute, Thrissur, Kerala, India for a duration of 18 months from January 2023 to June 2024. A total of 50 patients with intertrochanteric femur fractures were included in the study and divided into two groups: Group A (PFN with helical blade) and Group B (PFN with telescopic lag screw). Patients were assessed based on parameters such as time for union, neck shaft angle, Tip Apex Distance (TAD), Harris Hip Score, and complications. Statistical analysis was performed using SPSS software. Neck Shaft Angle was normal in 72% of Group A and 68% of Group B, with no significant difference, Tip Apex Distance (TAD) was higher in Group A at 4, 12, and 24 weeks follow-up, with statistical significance (p<0.05). Harris Hip Score was significantly higher in Group B at 4 weeks follow-up (p=0.014), but no significant difference at 12 and 24 weeks. 16% of patients in Group A experienced screw cut-out, which was statistically significant. One patient in each group experienced screw back-out. PFN with telescopic lag screw demonstrated superior outcomes compared to PFN with helical blade, particularly in terms of lower Tip Apex Distance, increased complication rates such as screw backout, screw cut out and higher Harris Hip Scores at early follow-up. A high Tip Apex Distance correlates with an increased risk of device cut-out from the femur head. Keywords :Unstable intertrochanteric fractures; Helical blade; Telescopic Lag screw; Tip Apex distance; Harris Hip Score

THE JOURNAL OF THE BULGARIAN ORTHOPAEDICS AND TRAUMA ASSOCIATIONVol. 62
Jubilee Mission Medical College and Research Institute (IN)
Openalex Percentile: Top 89%
Hip and Femur Fractures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.