Operation of nonlinear load in autonomous electric power supply systems from a gasoline generator

The influence of active, reactive and parametric electric load on the gasoline generator operation is studied. The influ-ence of various load parameters and components of the total power on the operation of the gasoline generator with regard to fuel consumption has been studied. In the course of the experiment the curves of the generator output voltage and the current consumed from it at change of load parameters in the nominal range of generator power are obtained. Experimentally taken curves of currents and voltages are decomposed by means of Fourier transform into harmonic components, after which the calculation of the components of the total power is carried out. According to the results of calculations, the effect on fuel consumption of the values of the components of full load power at their controlled vari-ation is established.

Authors

Publication Details

Journal
Известия высших учебных заведений Электромеханика
Published
2025-01-01
DOI
https://doi.org/10.17213/0136-3360-2025-1-30-37
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Operation of nonlinear load in autonomous electric power supply systems from a gasoline generator

K.H. Uzbekov, А. А. Шевцов, Evgeniy Glibin, Alexey Pryadilov
Известия высших учебных заведений Электромеханика
Multilevel Inverters and Converters
article

Operation of nonlinear load in autonomous electric power supply systems from a gasoline generator

K.H. Uzbekov, А. А. Шевцов, Evgeniy Glibin, Alexey Pryadilov
article en

Abstract

The influence of active, reactive and parametric electric load on the gasoline generator operation is studied. The influ-ence of various load parameters and components of the total power on the operation of the gasoline generator with regard to fuel consumption has been studied. In the course of the experiment the curves of the generator output voltage and the current consumed from it at change of load parameters in the nominal range of generator power are obtained. Experimentally taken curves of currents and voltages are decomposed by means of Fourier transform into harmonic components, after which the calculation of the components of the total power is carried out. According to the results of calculations, the effect on fuel consumption of the values of the components of full load power at their controlled vari-ation is established.

Известия высших учебных заведений ЭлектромеханикаVol. 68(1)
Openalex Percentile: Top 95%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.