A Calibration Procedure for Robotic Ultrasound Systems

With the rise of collaborative robots, there has been a growing interest in integrating ultrasound imaging with robotic systems in medical applications. This integration allows the system to receive real-time visual information, enabling the robot to move based on relevant anatomical features. However, for the visual information to be used accurately, it is essential to calibrate the pose of the ultrasound image in the robot’s coordinate frame. This paper presents a calibration technique that eliminates the need for external trackers and minimizes sources of error. The proposed method involves scanning a straight wire phantom with an unknown arrangement to constrain the set of possible solutions. By optimizing the cost function associated with the wires’ straightness, we can estimate the pose of the B-scan in the robot flange coordinate frame precisely and reliably without significant limitations, e.g., complex scanning trajectories. The technique shows an average precision of 0.8 mm and an accuracy of 1.72 mm with a scaling factor of 0.2778 mm/pixel.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Robotics and Bionics
Published
2025-04-01
DOI
https://doi.org/10.1109/tmrb.2025.3556549
Citations
2
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Calibration Procedure for Robotic Ultrasound Systems

Jorge Martins, João Oliveira, Rui Moura Coelho, Herculano Carvalho
2 citations
IEEE Transactions on Medical Robotics and Bionics
Soft Robotics and Applications
1.35
article

A Calibration Procedure for Robotic Ultrasound Systems

Jorge Martins, João Oliveira, Rui Moura Coelho, Herculano Carvalho
article en
2 citations

Abstract

With the rise of collaborative robots, there has been a growing interest in integrating ultrasound imaging with robotic systems in medical applications. This integration allows the system to receive real-time visual information, enabling the robot to move based on relevant anatomical features. However, for the visual information to be used accurately, it is essential to calibrate the pose of the ultrasound image in the robot’s coordinate frame. This paper presents a calibration technique that eliminates the need for external trackers and minimizes sources of error. The proposed method involves scanning a straight wire phantom with an unknown arrangement to constrain the set of possible solutions. By optimizing the cost function associated with the wires’ straightness, we can estimate the pose of the B-scan in the robot flange coordinate frame precisely and reliably without significant limitations, e.g., complex scanning trajectories. The technique shows an average precision of 0.8 mm and an accuracy of 1.72 mm with a scaling factor of 0.2778 mm/pixel.

IEEE Transactions on Medical Robotics and BionicsVol. 7(2)
Instituto de Engenharia de Sistemas e Computadores Investigação e Desenvolvimento (PT), Iscte – Instituto Universitário de Lisboa (PT), Hospital de Santa Maria (PT)
Fundação para a Ciência e a Tecnologia
Affordable and clean energy
Openalex Percentile: Top 21%
Soft Robotics and Applications
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.