Offline Versus Real-Time Grasp Prediction Employing a Wearable High-Density Lightmyography Armband: On the Control of Prosthetic Hands

Several studies over the last decades have investigated the use of myoelectric upper-arm prostheses to restore lost functionality and perform complex activities of daily life. Muscle-machine interfacing methods employing electromyography, sonomyography, forcemyography, and mechanomyography, have been developed offering users intuitive control of prostheses. However, these methods suffer their own drawbacks and the practical, robust, real-time control of prostheses in the execution of complex everyday life tasks remains difficult to accomplish. In this study, a wearable high-density lightmyography armband is proposed, and the offline and real-time grasp prediction schemes are compared in an attempt to deepen our understanding in real-time decoding employing lightmyography signals. Thus bringing lightmyography closer to advanced real-time prosthetic control scenarios. Offline experiments were conducted where models decoding 10 classes were trained and tested, achieving accuracies exceeding 91% with a mean of 94.11% when a Random Forest model was employed and a mean of 95.87% when a Convolutional Neural Networks model was employed. However, as models were deployed in real-time, a decline in performance was notable, reducing the accuracies to 60-70%. Other limitations were observed in this transition. Although average accuracies were high, the precision and recall for a small fraction of grasps were often low, hindering overall real-time performance. Moreover, prolonged usage led to decreased decoding accuracy, with accuracies dropping to below 35%, indicating that fatigue, sweat, or sensor shift may have affected the signals over time. Thus for the real-time application of lightmyography, it is recommended to discriminate between a smaller number of classes for which accuracies are higher (around 80% for 6 classes without prolonged use).

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3556920
Citations
3
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
2.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Offline Versus Real-Time Grasp Prediction Employing a Wearable High-Density Lightmyography Armband: On the Control of Prosthetic Hands

Minas Liarokapis, Mojtaba Shahmohammadi, Anany Dwivedi, Ricardo V. Godoy et al.
3 citations
IEEE Access
Muscle activation and electromyography studies
2.02
article

Offline Versus Real-Time Grasp Prediction Employing a Wearable High-Density Lightmyography Armband: On the Control of Prosthetic Hands

Minas Liarokapis, Mojtaba Shahmohammadi, Anany Dwivedi, Ricardo V. Godoy, Bonnie Guan
article en
3 citations

Abstract

Several studies over the last decades have investigated the use of myoelectric upper-arm prostheses to restore lost functionality and perform complex activities of daily life. Muscle-machine interfacing methods employing electromyography, sonomyography, forcemyography, and mechanomyography, have been developed offering users intuitive control of prostheses. However, these methods suffer their own drawbacks and the practical, robust, real-time control of prostheses in the execution of complex everyday life tasks remains difficult to accomplish. In this study, a wearable high-density lightmyography armband is proposed, and the offline and real-time grasp prediction schemes are compared in an attempt to deepen our understanding in real-time decoding employing lightmyography signals. Thus bringing lightmyography closer to advanced real-time prosthetic control scenarios. Offline experiments were conducted where models decoding 10 classes were trained and tested, achieving accuracies exceeding 91% with a mean of 94.11% when a Random Forest model was employed and a mean of 95.87% when a Convolutional Neural Networks model was employed. However, as models were deployed in real-time, a decline in performance was notable, reducing the accuracies to 60-70%. Other limitations were observed in this transition. Although average accuracies were high, the precision and recall for a small fraction of grasps were often low, hindering overall real-time performance. Moreover, prolonged usage led to decreased decoding accuracy, with accuracies dropping to below 35%, indicating that fatigue, sweat, or sensor shift may have affected the signals over time. Thus for the real-time application of lightmyography, it is recommended to discriminate between a smaller number of classes for which accuracies are higher (around 80% for 6 classes without prolonged use).

IEEE AccessVol. 13
Waikato Institute of Technology (NZ), University of Auckland (NZ), University of Waikato (NZ)
Openalex Percentile: Top 15%
Muscle activation and electromyography studies
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.