High-Sensitivity Sapphire Vacuum Fiber Pressure Sensor for High Temperature Applications

A high-sensitivity sapphire extrinsic Fabry-Perot (FP) interferometer (EFPI) is proposed for the high-resolution pressure measurement in high temperature vacuum environment. A composite FP cavity structure is fabricated by directly bonding three sapphire wafers with different thickness to simultaneously measure temperature and pressure, which can effectively address the cross-sensitivity problem from temperature to pressure. Experimental results show that the pressure can be accurately measured from 0 to 100 kPa within the temperature range of 29 °C–800 °C. The optical cavity length (OCL) of the sealed air cavity varies linearly with pressure, and the pressure sensitivity increases with temperature, resulting in a maximum error of 4.3 kPa. The pressure sensitivities are 56.22 and 63.24 nm/kPa at room temperature and 800 °C, and the resolutions of pressure measurement are 17.79 and 15.81 Pa, respectively. Based on its excellent performance, the proposed high-sensitivity EFPI is a prospective sensor for measuring the vacuum pressure in high temperature environment.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-04-01
DOI
https://doi.org/10.1109/jsen.2025.3554262
Citations
4
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
2.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Sensitivity Sapphire Vacuum Fiber Pressure Sensor for High Temperature Applications

Yutong Zhang, Zhao Shuang, Yi Jiang, Hui Deng
4 citations
IEEE Sensors Journal
Advanced Fiber Optic Sensors
2.92
article

High-Sensitivity Sapphire Vacuum Fiber Pressure Sensor for High Temperature Applications

Yutong Zhang, Zhao Shuang, Yi Jiang, Hui Deng
article en
4 citations

Abstract

A high-sensitivity sapphire extrinsic Fabry-Perot (FP) interferometer (EFPI) is proposed for the high-resolution pressure measurement in high temperature vacuum environment. A composite FP cavity structure is fabricated by directly bonding three sapphire wafers with different thickness to simultaneously measure temperature and pressure, which can effectively address the cross-sensitivity problem from temperature to pressure. Experimental results show that the pressure can be accurately measured from 0 to 100 kPa within the temperature range of 29 °C–800 °C. The optical cavity length (OCL) of the sealed air cavity varies linearly with pressure, and the pressure sensitivity increases with temperature, resulting in a maximum error of 4.3 kPa. The pressure sensitivities are 56.22 and 63.24 nm/kPa at room temperature and 800 °C, and the resolutions of pressure measurement are 17.79 and 15.81 Pa, respectively. Based on its excellent performance, the proposed high-sensitivity EFPI is a prospective sensor for measuring the vacuum pressure in high temperature environment.

IEEE Sensors JournalVol. 25(10)
Beijing Institute of Technology (CN), Baotou Teachers College (CN), Ministry of Industry and Information Technology (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 10%
Advanced Fiber Optic Sensors
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-Sensitivity Sapphire Vacuum Fiber Pressure Sensor for High Temperature Applications — Yutong Zhang, Zhao Shuang, et al. · IEEE Sensors Journal (2025) | TGRS Research Map | TGRS