Structural Response of Beam-Column Joint Made of Fiber Reinforced Concrete (FRC) Using Ansys Fea Simulation

Beam-column joints are crucial in reinforced concrete and steel structures, which transfer load from beams to columns and vice versa. They are essential to withstand various types of loads, such as lateral, gravity, and seismic loads. The material of the beam-column joint determines the joint's ability to withstand and transfer loads between beams and columns. The stronger material would enhance its strength and overall load-bearing capacity and vice versa. Current research aims to evaluate the structural response of beam-column joints made of Fiber Reinforced Concrete (FRC's) using ANSYS FEA simulation package. The effect of fiber concentration, i.e., 0.3%, 0.6%, and 0.9%, on the strength of the beam-column joint is evaluated based on structural evaluation parameters. The other objective is to evaluate the effect of graphene fiber (the aspect ratio is 1:1, although up to 1.5 is typically acceptable) on improving the strength of the beam-column joint. Comparative studies are conducted, and materials are evaluated based on stiffness, ductility and energy dissipation. The graphene-reinforced concrete demonstrates less stiffness degradation with increased strain. This indicates that the incorporation of graphene improves the stiffness retention capacity of the concrete. The hysteresis loop of graphene-reinforced concrete is broader, signifying enhanced ductility. This indicates that the material can sustain greater deformations without failure, essential for seismic performance. The 0% FRC has minimal ductility, characterized by a notable reduction in stress upon first loading. The 0.3% and 0.6% FRC show improved ductility, with higher stress levels maintained over larger strains. The 0.9% FRC demonstrates the highest ductility, maintaining higher stress over the full strain range, indicating it can undergo larger deformations without failure. The stiffness degradation is less pronounced in higher FRC concentrations.

Authors

Institutions

Publication Details

Journal
Rocznik Ochrona Środowiska
Published
2025-04-02
DOI
https://doi.org/10.54740/ros.2025.015
Citations
3
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
2.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural Response of Beam-Column Joint Made of Fiber Reinforced Concrete (FRC) Using Ansys Fea Simulation

Luxmi Gautam, Parveen Berwal, Isha Verma, Anuj Gupta et al.
3 citations
Rocznik Ochrona Środowiska
Structural Load-Bearing Analysis
2.86
article

Structural Response of Beam-Column Joint Made of Fiber Reinforced Concrete (FRC) Using Ansys Fea Simulation

Luxmi Gautam, Parveen Berwal, Isha Verma, Anuj Gupta, Saiful Islam, Abdullah Faiz Al Asmari, Shruti Gomkale
article en
3 citations

Abstract

Beam-column joints are crucial in reinforced concrete and steel structures, which transfer load from beams to columns and vice versa. They are essential to withstand various types of loads, such as lateral, gravity, and seismic loads. The material of the beam-column joint determines the joint's ability to withstand and transfer loads between beams and columns. The stronger material would enhance its strength and overall load-bearing capacity and vice versa. Current research aims to evaluate the structural response of beam-column joints made of Fiber Reinforced Concrete (FRC's) using ANSYS FEA simulation package. The effect of fiber concentration, i.e., 0.3%, 0.6%, and 0.9%, on the strength of the beam-column joint is evaluated based on structural evaluation parameters. The other objective is to evaluate the effect of graphene fiber (the aspect ratio is 1:1, although up to 1.5 is typically acceptable) on improving the strength of the beam-column joint. Comparative studies are conducted, and materials are evaluated based on stiffness, ductility and energy dissipation. The graphene-reinforced concrete demonstrates less stiffness degradation with increased strain. This indicates that the incorporation of graphene improves the stiffness retention capacity of the concrete. The hysteresis loop of graphene-reinforced concrete is broader, signifying enhanced ductility. This indicates that the material can sustain greater deformations without failure, essential for seismic performance. The 0% FRC has minimal ductility, characterized by a notable reduction in stress upon first loading. The 0.3% and 0.6% FRC show improved ductility, with higher stress levels maintained over larger strains. The 0.9% FRC demonstrates the highest ductility, maintaining higher stress over the full strain range, indicating it can undergo larger deformations without failure. The stiffness degradation is less pronounced in higher FRC concentrations.

Rocznik Ochrona ŚrodowiskaVol. 27
Galgotias University (IN), Yashwantrao Chavan Maharashtra Open University (IN), GLA University (IN), King Khalid University (SA), Maharshi Dayanand University (IN)
Openalex Percentile: Top 11%
Structural Load-Bearing Analysis
2.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.