The Incorporating ANFIS-based current regulation into a multi-active full bridge converter for reducing current ripple

   A multi-active full bridge converter is a type of DC-DC converter typically used in high-power applications like renewable energy systems, electric vehicles, or uninterruptible power supplies. Four switches (often MOSFETs or IGBTs) grouped in an H-bridge configuration make up the full bridge topology. The term "multi-active" implies that the power conversion involves a number of active components, which may indicate complicated switching management for improved efficiency and regulation. Changing the phase shift between two switch pairs is how phase-shifted full-bridge converters are controlled. Without altering the switching frequency, the output voltage can be controlled by adjusting the phase difference between the bridge's two legs (S1-S4 and S2-S3). To lower switching losses, soft switching strategies like ZVS or ZCS might be used. improving overall efficiency. In this approach, the current through the switches is monitored and controlled to improve transient response and stability. Typically implemented in combination with voltage mode control, it ensures better regulation, especially in systems with fast load changes. The secondary side full bridge switches are controlled by current feedback phase delay controller which restricts the battery charge current. Each EV battery has its own charge current limit which is set in the current controller for battery protection. The controlled charge current improves the charge efficiency of the EV battery increasing the reliability of the cells and the overall circuit. The charge control which is a conventional PI controller is further updated with ANFIS for better stability in the EV battery charging current. A comparative analysis with PI and ANFIS controllers is proposed and the results are generated with same rating of EV batteries and system parameters. 

Authors

Publication Details

Journal
ITEGAM- Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA)
Published
2025-01-01
DOI
https://doi.org/10.5935/jetia.v11i52.1550
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Incorporating ANFIS-based current regulation into a multi-active full bridge converter for reducing current ripple

G Rathod Rama Krishna, Punnaiah Veeraboina Yesuratnam
ITEGAM- Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA)
Machine Fault Diagnosis Techniques
article

The Incorporating ANFIS-based current regulation into a multi-active full bridge converter for reducing current ripple

G Rathod Rama Krishna, Punnaiah Veeraboina Yesuratnam
article en

Abstract

   A multi-active full bridge converter is a type of DC-DC converter typically used in high-power applications like renewable energy systems, electric vehicles, or uninterruptible power supplies. Four switches (often MOSFETs or IGBTs) grouped in an H-bridge configuration make up the full bridge topology. The term "multi-active" implies that the power conversion involves a number of active components, which may indicate complicated switching management for improved efficiency and regulation. Changing the phase shift between two switch pairs is how phase-shifted full-bridge converters are controlled. Without altering the switching frequency, the output voltage can be controlled by adjusting the phase difference between the bridge's two legs (S1-S4 and S2-S3). To lower switching losses, soft switching strategies like ZVS or ZCS might be used. improving overall efficiency. In this approach, the current through the switches is monitored and controlled to improve transient response and stability. Typically implemented in combination with voltage mode control, it ensures better regulation, especially in systems with fast load changes. The secondary side full bridge switches are controlled by current feedback phase delay controller which restricts the battery charge current. Each EV battery has its own charge current limit which is set in the current controller for battery protection. The controlled charge current improves the charge efficiency of the EV battery increasing the reliability of the cells and the overall circuit. The charge control which is a conventional PI controller is further updated with ANFIS for better stability in the EV battery charging current. A comparative analysis with PI and ANFIS controllers is proposed and the results are generated with same rating of EV batteries and system parameters. 

ITEGAM- Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA)Vol. 11(52)
Affordable and clean energy
Openalex Percentile: Top 93%
Machine Fault Diagnosis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Incorporating ANFIS-based current regulation into a multi-active full bridge converter for reducing current ripple — G Rathod Rama Krishna, Punnaiah Veeraboina Yesuratnam · ITEGAM- Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA) (2025) | TGRS Research Map | TGRS