Electrochemical detection of tetracycline by zinc oxide modified with molecularly-imprinted polymers

An efficient electrochemical molecularly imprinted sensor for the detection of tetracycline (TC) was prepared using ZnO/MIP. ZnO nanomaterials with large surface area improved the electrochemical detection performance and also increased the binding sites of the TC molecularly imprinted polymeric membrane. The TC molecularly imprinted polymeric membrane with pyrrole as the functional monomer specifically binds to TC and thus detects TC in the sample. In this study, the electrochemical performance of ZnO/MIP was evaluated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Under the optimal conditions, ZnO/MIP showed a wide detection range. The detection range was 0.1-100 nM, and the detection limit was 0.02 nM with <i>R</i><sup>2</sup> reaching 0.9974. ZnO/MIP has good selectivity, stability, and reproducibility. The recovery of tetracycline in milk was 97-112%.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay00270b
Citations
2
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
1.50
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical detection of tetracycline by zinc oxide modified with molecularly-imprinted polymers

Dongpo Xu, Haoxiang Wang, Mengqi Lu, Ruoyu Wang et al.
2 citations
Analytical Methods
Analytical chemistry methods development
1.50
article

Electrochemical detection of tetracycline by zinc oxide modified with molecularly-imprinted polymers

Dongpo Xu, Haoxiang Wang, Mengqi Lu, Ruoyu Wang, Yiwei Sun, Yuyang He, Yuting Luo
article en
2 citations

Abstract

An efficient electrochemical molecularly imprinted sensor for the detection of tetracycline (TC) was prepared using ZnO/MIP. ZnO nanomaterials with large surface area improved the electrochemical detection performance and also increased the binding sites of the TC molecularly imprinted polymeric membrane. The TC molecularly imprinted polymeric membrane with pyrrole as the functional monomer specifically binds to TC and thus detects TC in the sample. In this study, the electrochemical performance of ZnO/MIP was evaluated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Under the optimal conditions, ZnO/MIP showed a wide detection range. The detection range was 0.1-100 nM, and the detection limit was 0.02 nM with <i>R</i><sup>2</sup> reaching 0.9974. ZnO/MIP has good selectivity, stability, and reproducibility. The recovery of tetracycline in milk was 97-112%.

Analytical MethodsVol. 17(15)
University of Shanghai for Science and Technology (CN)
Openalex Percentile: Top 21%
Analytical chemistry methods development
1.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electrochemical detection of tetracycline by zinc oxide modified with molecularly-imprinted polymers — Dongpo Xu, Haoxiang Wang, et al. · Analytical Methods (2025) | TGRS Research Map | TGRS