Measurement setup for the characterization of integrated semiconductor circuits at cryogenic temperatures

Integrated semiconductor circuits operating at cryogenic temperatures can play a crucial role in scaling quantum computing architectures based on trapped-ion and superconducting qubits. Other technologies, such as low-temperature detectors, can also benefit significantly from these circuits. These applications demand high-frequency, cryogenic temperature measurement systems for the thorough characterization of semiconductor components and circuits. This work presents a customizable, high-frequency, fast, and reliable cryogenic measurement setup for measurement temperatures ranging from room temperature to 4.2 K. It features up to two dc probes or two ground-signal-ground probes for frequencies of up to 67 GHz, which can be configured in a 180° or 90° configuration. In addition, up to 48 BeCu wires configured as twisted pairs provide supply and control signals. Furthermore, up to four rf connections can be mounted directly to a printed circuit board. The setup features an optical microscope in the vacuum chamber to position the probes, which is further utilized by a machine vision algorithm, allowing the detection of pads and automatic positioning of the probes over the pads. The hardware is located in a 550 × 500 × 500 mm3 large vacuum chamber with two independent pulse tube cryocoolers with cooling powers of up to 0.9 and 0.4 W at 4.2 K. Exemplary room temperature and cryogenic S-parameter, transient frequency (fT), time-domain, capacitance-voltage, and dc measurements of single transistors and integrated circuits fabricated by Infineon are presented, demonstrating the system's measurement capability for quantum computing and other applications.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-04-01
DOI
https://doi.org/10.1063/5.0245525
Citations
5
Primary Topic
Advancements in Semiconductor Devices and Circuit Design
Type
article
Field-Weighted Citation Impact
3.65

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement setup for the characterization of integrated semiconductor circuits at cryogenic temperatures

Paul Julius Ritter, Benedikt Hampel, Вадим Іссаков, Andreas Pawlak et al.
5 citations
Review of Scientific Instruments
Advancements in Semiconductor Devices and Circuit Design
3.65
article

Measurement setup for the characterization of integrated semiconductor circuits at cryogenic temperatures

Paul Julius Ritter, Benedikt Hampel, Вадим Іссаков, Andreas Pawlak, Julius Mumme, Alexander Meyer, Meinhard Schilling, Marius Neumann, Zaibing Guo, Marc-André Tucholke, R. Roederer
article en
5 citations

Abstract

Integrated semiconductor circuits operating at cryogenic temperatures can play a crucial role in scaling quantum computing architectures based on trapped-ion and superconducting qubits. Other technologies, such as low-temperature detectors, can also benefit significantly from these circuits. These applications demand high-frequency, cryogenic temperature measurement systems for the thorough characterization of semiconductor components and circuits. This work presents a customizable, high-frequency, fast, and reliable cryogenic measurement setup for measurement temperatures ranging from room temperature to 4.2 K. It features up to two dc probes or two ground-signal-ground probes for frequencies of up to 67 GHz, which can be configured in a 180° or 90° configuration. In addition, up to 48 BeCu wires configured as twisted pairs provide supply and control signals. Furthermore, up to four rf connections can be mounted directly to a printed circuit board. The setup features an optical microscope in the vacuum chamber to position the probes, which is further utilized by a machine vision algorithm, allowing the detection of pads and automatic positioning of the probes over the pads. The hardware is located in a 550 × 500 × 500 mm3 large vacuum chamber with two independent pulse tube cryocoolers with cooling powers of up to 0.9 and 0.4 W at 4.2 K. Exemplary room temperature and cryogenic S-parameter, transient frequency (fT), time-domain, capacitance-voltage, and dc measurements of single transistors and integrated circuits fabricated by Infineon are presented, demonstrating the system's measurement capability for quantum computing and other applications.

Review of Scientific InstrumentsVol. 96(4)
Infineon Technologies (United Kingdom) (GB), Technische Universität Braunschweig (DE)
Deutsche Forschungsgemeinschaft, Volkswagen Foundation, Bundesministerium für Bildung und Forschung
Affordable and clean energy
Openalex Percentile: Top 7%
Advancements in Semiconductor Devices and Circuit Design
3.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.