A CMOS Instrumentation Amplifier for Photoacoustic Signal Measurement

The design of a low noise, high bandwidth, and high-speed instrumentation amplifier tuned for accurate measurement of photoacoustic signals in biomedical applications is presented. The designed amplifier's gain and bandwidth are tunable up to 54.3 dB and 166.12 kHz respectively. Besides, a gain-dependent high CMRR of up to 114.4 dB with at least 102 dB (-) and 67 dB (+) PSRR, along with only 40.88 nV/Hz input referred thermal noise and choice of 2 pF capacitive load make the amplifier immune to noisy environments. Additionally, the 2 pF capacitive load ensures a fast response of the instrumentation amplifier.

Authors

Institutions

Publication Details

Published
2024-11-01
DOI
https://doi.org/10.1109/spicscon64195.2024.10940730
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A CMOS Instrumentation Amplifier for Photoacoustic Signal Measurement

Md. Mahabub Hossain, Md. Tasfiq Rahman, Md Shadhin, Sajib Biswas Shuvo et al.
Photoacoustic and Ultrasonic Imaging
article

A CMOS Instrumentation Amplifier for Photoacoustic Signal Measurement

Md. Mahabub Hossain, Md. Tasfiq Rahman, Md Shadhin, Sajib Biswas Shuvo, Wasifa Mashiyath
article en

Abstract

The design of a low noise, high bandwidth, and high-speed instrumentation amplifier tuned for accurate measurement of photoacoustic signals in biomedical applications is presented. The designed amplifier's gain and bandwidth are tunable up to 54.3 dB and 166.12 kHz respectively. Besides, a gain-dependent high CMRR of up to 114.4 dB with at least 102 dB (-) and 67 dB (+) PSRR, along with only 40.88 nV/Hz input referred thermal noise and choice of 2 pF capacitive load make the amplifier immune to noisy environments. Additionally, the 2 pF capacitive load ensures a fast response of the instrumentation amplifier.

Bangladesh University of Engineering and Technology (BD)
Affordable and clean energy
Openalex Percentile: Top 75%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.