Artifact Reduction 3.0 T <scp>MRI</scp> in Cochlear Implantation Recipient With Diametrically Bipolar Magnets

ABSTRACT Objectives This study aims to explore the clinical results of the MAVRIC‐SL sequence in 3.0 Tesla (T) magnetic resonance imaging (MRI) examination of cochlear implant recipients with diametrically bipolar magnets. Study Design Retrospective study. Methods Six consecutive patients implanted with diametrically bipolar magnets received a 3.0 T MRI for necessary reexaminations. The artifact volumes (cm 3 ) and maximum artifact areas (cm 2 ) were measured before and after applying the MAVRIC‐SL. Adverse events, including discomfort or pain (measured using VAS), skin temperatures, and magnet displacement, were also recorded. Results All enrolled patients completed the MRI scans. Significant reductions in artifact volumes and maximum areas were observed with the MAVRIC‐SL sequence compared to others ( p &lt; 0.05 to &lt; 0.01). Targeted disease regions, as well as the inner ear anatomy, were clearly revealed with MAVRIC‐SL. One patient (aged 12) reported pain (VAS score: 8) during the scan, while others (aged 10–36) did not experience discomfort. Neither displacement nor tilt of the internal magnet was seen. Conclusion The MAVRIC‐SL sequence represents a feasible and safe solution for 3 T MRI in cochlear implanters with diametrically bipolar magnets, providing a new option to meet clinical needs. Level of Evidence 4.

Authors

Institutions

Publication Details

Journal
The Laryngoscope
Published
2025-04-01
DOI
https://doi.org/10.1002/lary.32114
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artifact Reduction 3.0 T MRI in Cochlear Implantation Recipient With Diametrically Bipolar Magnets

Jincangjian Sun, Xiaoqing Cen, Guanxia Xiong, Qin Xiong et al.
The Laryngoscope
Advanced MRI Techniques and Applications
article

Artifact Reduction 3.0 T MRI in Cochlear Implantation Recipient With Diametrically Bipolar Magnets

Jincangjian Sun, Xiaoqing Cen, Guanxia Xiong, Qin Xiong, Kaitian Chen, Chunxiang Zhou, Meng Wang, Huiwen Zhuang
article en

Abstract

ABSTRACT Objectives This study aims to explore the clinical results of the MAVRIC‐SL sequence in 3.0 Tesla (T) magnetic resonance imaging (MRI) examination of cochlear implant recipients with diametrically bipolar magnets. Study Design Retrospective study. Methods Six consecutive patients implanted with diametrically bipolar magnets received a 3.0 T MRI for necessary reexaminations. The artifact volumes (cm 3 ) and maximum artifact areas (cm 2 ) were measured before and after applying the MAVRIC‐SL. Adverse events, including discomfort or pain (measured using VAS), skin temperatures, and magnet displacement, were also recorded. Results All enrolled patients completed the MRI scans. Significant reductions in artifact volumes and maximum areas were observed with the MAVRIC‐SL sequence compared to others ( p &lt; 0.05 to &lt; 0.01). Targeted disease regions, as well as the inner ear anatomy, were clearly revealed with MAVRIC‐SL. One patient (aged 12) reported pain (VAS score: 8) during the scan, while others (aged 10–36) did not experience discomfort. Neither displacement nor tilt of the internal magnet was seen. Conclusion The MAVRIC‐SL sequence represents a feasible and safe solution for 3 T MRI in cochlear implanters with diametrically bipolar magnets, providing a new option to meet clinical needs. Level of Evidence 4.

The LaryngoscopeVol. 135(8)
Sun Yat-sen University (CN), The First Affiliated Hospital, Sun Yat-sen University (CN)
Openalex Percentile: Top 90%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.