Accuracy evaluation of primary frequency standard NIST-F4

Abstract This work describes the apparatus for NIST-F4, an updated cesium atomic fountain at the National Institute of Standards and Technology (NIST), and presents an accuracy evaluation of the fountain as a primary frequency standard. The fountain uses optical molasses to laser cool a cloud of cesium atoms and launch it vertically in a fountain geometry. In high-density mode, the fractional frequency stability of NIST-F4 is <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>σ</mml:mi> <mml:mi>y</mml:mi> </mml:msub> <mml:mo stretchy="false">(</mml:mo> <mml:mi>τ</mml:mi> <mml:mo stretchy="false">)</mml:mo> <mml:mo>=</mml:mo> <mml:mn>1.5</mml:mn> <mml:mo>×</mml:mo> <mml:msup> <mml:mn>10</mml:mn> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>13</mml:mn> </mml:mrow> </mml:msup> <mml:mrow> <mml:mo>/</mml:mo> </mml:mrow> <mml:msqrt> <mml:mi>τ</mml:mi> </mml:msqrt> </mml:mrow> </mml:math> , where τ is the measurement time in seconds. The short-term stability is limited by quantum projection noise and by phase noise from the local oscillator, an oven-controlled crystal oscillator operating at 5 MHz. Systematic frequency shifts and their uncertainties have been evaluated, resulting in a systematic (type B) fractional frequency uncertainty <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>σ</mml:mi> <mml:mrow> <mml:mi mathvariant="normal">B</mml:mi> </mml:mrow> </mml:msub> <mml:mo>=</mml:mo> <mml:mn>2.2</mml:mn> <mml:mo>×</mml:mo> <mml:msup> <mml:mn>10</mml:mn> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>16</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> .

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2025-04-01
DOI
https://doi.org/10.1088/1681-7575/adc7bd
Citations
6
Primary Topic
Advanced Electrical Measurement Techniques
Type
article
Field-Weighted Citation Impact
4.38

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy evaluation of primary frequency standard NIST-F4

Kurt Gibble, Thomas P. Heavner, Gregory W. Hoth, T.E. Parker et al.
6 citations
Metrologia
Advanced Electrical Measurement Techniques
4.38
article

Accuracy evaluation of primary frequency standard NIST-F4

Kurt Gibble, Thomas P. Heavner, Gregory W. Hoth, T.E. Parker, Vladislav Gerginov, Jeffrey A. Sherman
article en
6 citations

Abstract

Abstract This work describes the apparatus for NIST-F4, an updated cesium atomic fountain at the National Institute of Standards and Technology (NIST), and presents an accuracy evaluation of the fountain as a primary frequency standard. The fountain uses optical molasses to laser cool a cloud of cesium atoms and launch it vertically in a fountain geometry. In high-density mode, the fractional frequency stability of NIST-F4 is <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>σ</mml:mi> <mml:mi>y</mml:mi> </mml:msub> <mml:mo stretchy="false">(</mml:mo> <mml:mi>τ</mml:mi> <mml:mo stretchy="false">)</mml:mo> <mml:mo>=</mml:mo> <mml:mn>1.5</mml:mn> <mml:mo>×</mml:mo> <mml:msup> <mml:mn>10</mml:mn> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>13</mml:mn> </mml:mrow> </mml:msup> <mml:mrow> <mml:mo>/</mml:mo> </mml:mrow> <mml:msqrt> <mml:mi>τ</mml:mi> </mml:msqrt> </mml:mrow> </mml:math> , where τ is the measurement time in seconds. The short-term stability is limited by quantum projection noise and by phase noise from the local oscillator, an oven-controlled crystal oscillator operating at 5 MHz. Systematic frequency shifts and their uncertainties have been evaluated, resulting in a systematic (type B) fractional frequency uncertainty <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>σ</mml:mi> <mml:mrow> <mml:mi mathvariant="normal">B</mml:mi> </mml:mrow> </mml:msub> <mml:mo>=</mml:mo> <mml:mn>2.2</mml:mn> <mml:mo>×</mml:mo> <mml:msup> <mml:mn>10</mml:mn> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>16</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> .

MetrologiaVol. 62(3)
Pennsylvania State University (US), National Institute of Standards and Technology (US)
Directorate for Mathematical and Physical Sciences, National Institute of Standards and Technology
Openalex Percentile: Top 6%
Advanced Electrical Measurement Techniques
4.38
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.