Challenges in Detecting Hydroxyl Radicals Generated in Water Droplets with Mass Spectrometry

Water is sprayed into the air using three distinct methods: (1) nanoelectrospray ionization, (2) a vibrating membrane nebulizer, and (3) a pneumatic nebulizer. The resulting droplets are analyzed by three different mass analyzers: (a) a linear ion trap mass analyzer on an <i>LTQ-XL</i> mass spectrometer, (b) the <i>Velos Pro</i> dual-pressure linear ion trap mass analyzer on an <i>Orbitrap Elite</i> mass spectrometer, and (c) the Orbitrap mass analyzer on the same <i>Orbitrap Elite</i> system. We searched for hydroxyl radical adducts with hydronium ions (OH•-H<sub>3</sub>O<sup>+</sup>) or reaction products with caffeine dissolved in water and with melatonin dissolved in water. These experiments were repeated in several different laboratories, and all results were the same. The oxidation products of caffeine and melatonin were not detected when using the Orbitrap mass analyzer having a much longer holding time in the ion trap (500 ms) but could be observed with reduced intensity at much shorter holding times (<10 ms). The signal of OH•-H<sub>3</sub>O<sup>+</sup> was also significantly reduced when using the <i>Velos Pro</i> dual-pressure linear ion trap mass analyzer. These results suggest that ion signals from fragile radicals may be diminished or lost depending on the mass detection system and operating conditions employed, and there may be a risk of obtaining spurious results when using an Orbitrap mass spectrometer.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-04-01
DOI
https://doi.org/10.1021/acs.analchem.5c00386
Citations
19
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
14.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Challenges in Detecting Hydroxyl Radicals Generated in Water Droplets with Mass Spectrometry

Richard N. Zare, Xufeng Gao, Yifan Meng, Chongqin Zhu et al.
19 citations
Analytical Chemistry
Mass Spectrometry Techniques and Applications
14.37
article

Challenges in Detecting Hydroxyl Radicals Generated in Water Droplets with Mass Spectrometry

Richard N. Zare, Xufeng Gao, Yifan Meng, Chongqin Zhu, Madison E. Edwards, Chiyu Liang, Jianze Zhang, Huan Chen, Xinxing Zhang, Dong Xing, Yu Xia
article en
19 citations

Abstract

Water is sprayed into the air using three distinct methods: (1) nanoelectrospray ionization, (2) a vibrating membrane nebulizer, and (3) a pneumatic nebulizer. The resulting droplets are analyzed by three different mass analyzers: (a) a linear ion trap mass analyzer on an <i>LTQ-XL</i> mass spectrometer, (b) the <i>Velos Pro</i> dual-pressure linear ion trap mass analyzer on an <i>Orbitrap Elite</i> mass spectrometer, and (c) the Orbitrap mass analyzer on the same <i>Orbitrap Elite</i> system. We searched for hydroxyl radical adducts with hydronium ions (OH•-H<sub>3</sub>O<sup>+</sup>) or reaction products with caffeine dissolved in water and with melatonin dissolved in water. These experiments were repeated in several different laboratories, and all results were the same. The oxidation products of caffeine and melatonin were not detected when using the Orbitrap mass analyzer having a much longer holding time in the ion trap (500 ms) but could be observed with reduced intensity at much shorter holding times (<10 ms). The signal of OH•-H<sub>3</sub>O<sup>+</sup> was also significantly reduced when using the <i>Velos Pro</i> dual-pressure linear ion trap mass analyzer. These results suggest that ion signals from fragile radicals may be diminished or lost depending on the mass detection system and operating conditions employed, and there may be a risk of obtaining spurious results when using an Orbitrap mass spectrometer.

Analytical ChemistryVol. 97(14)
Johns Hopkins University (US), Nankai University (CN), Beijing Normal University (CN), Mitchell Institute (US), Jianghan University (CN), Advanced Energy Materials (United States) (US), Texas A&M University (US), Stanford University (US)
National Natural Science Foundation of China, Natural Science Foundation of Tianjin City, National Key Research and Development Program of China
Clean water and sanitation
Openalex Percentile: Top 1%
Mass Spectrometry Techniques and Applications
14.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.