Design and Comparison of Controllers for a Robotic Transfemoral Prosthesis

This study investigates the performance of four control strategies—Proportional-Derivative (PD), Feedforward-Feedback PD (FF-FB PD), Linear Quadratic Regulator (LQR), and Feedforward-Feedback LQR (FF-FB LQR)—implemented on a robotic transfemoral prosthesis. The performance metrics, including overshoot, settling time, trajectory tracking accuracy, and torque requirements, were evaluated using simulation models. The results indicate that the FF-FB LQR controller demonstrated superior performance, achieving the lowest overshoot (4.98%) and near-zero trajectory tracking error. All controllers required approximately 8.6 Nm of torque, suggesting consistent energy requirements across strategies despite their performance differences. The LQR controller exhibited the best stability, minimizing overshoot and improving overall system response. These findings highlight the advantages of feedforward-feedback control strategies, particularly the FF-FB LQR, for controlling robotic transfemoral prostheses with enhanced stability and accuracy.

Authors

Institutions

Publication Details

Journal
Data & Metadata
Published
2025-03-28
DOI
https://doi.org/10.56294/dm2025759
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Comparison of Controllers for a Robotic Transfemoral Prosthesis

Christian Rueda, Vladimir Bonilla, Guillermo Mosquera, Sofía Vergara et al.
Data & Metadata
Prosthetics and Rehabilitation Robotics
article

Design and Comparison of Controllers for a Robotic Transfemoral Prosthesis

Christian Rueda, Vladimir Bonilla, Guillermo Mosquera, Sofía Vergara, Marcelo Moya
article en

Abstract

This study investigates the performance of four control strategies—Proportional-Derivative (PD), Feedforward-Feedback PD (FF-FB PD), Linear Quadratic Regulator (LQR), and Feedforward-Feedback LQR (FF-FB LQR)—implemented on a robotic transfemoral prosthesis. The performance metrics, including overshoot, settling time, trajectory tracking accuracy, and torque requirements, were evaluated using simulation models. The results indicate that the FF-FB LQR controller demonstrated superior performance, achieving the lowest overshoot (4.98%) and near-zero trajectory tracking error. All controllers required approximately 8.6 Nm of torque, suggesting consistent energy requirements across strategies despite their performance differences. The LQR controller exhibited the best stability, minimizing overshoot and improving overall system response. These findings highlight the advantages of feedforward-feedback control strategies, particularly the FF-FB LQR, for controlling robotic transfemoral prostheses with enhanced stability and accuracy.

Data & MetadataVol. 4
Instituto Nacional de Biodiversidad (EC), Universidad Internacional del Ecuador (EC)
Openalex Percentile: Top 94%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.