MeMGB-Diff: Memory-Efficient Multivariate Gaussian Bias Diffusion Model for 3D bias field correction

Bias fields inevitably degrade MRI that seriously interferes the diagnosis of physicians for accurate analysis, and removing it is a crucial image analysis task. Generative models (such as GANs) are used for bias field correction, and outperform traditional methods, however are hindered by the high cost of data annotation and instability during training. Recently, the diffusion-based methods have excelled over GANs in many applications, and they are powerful in removing noise from images, while the bias field can be regarded as a smooth noise. However, it is a challenge to directly apply to 3D bias field correction due to sampling inefficiency, the heavy computational demand, and implicit correction process. We propose a Memory-Efficient Multivariate Gaussian Bias Diffusion Model (MeMGB-Diff) that is an explicit, sampling, and memory both efficient diffusion model for 3D bias field correction without using clinical labels. MeMGB-Diff extends the diffusion models to multivariate Gaussian and models the bias field as a multivariate Gaussian variable, allowing direct diffusion and removal of the 3D bias fields without Gaussian noise. For memory efficiency, MeMGB-Diff performs diffusion model in smaller readable image domain at the expense of a negligible accuracy loss, based on the strong correlation among adjacent voxels of bias field. We also propose a loss function to mainly learn the intensity trend, which mainly causes the inhomogeneity of MRI, and effectively increases the correction accuracy. For comprehensive performance comparison, we propose a synthetic method for generating more varied bias fields during testing. Both quantitative and qualitative assessments on synthetic and clinical data confirm the high fidelity and uniform intensity of our results. MeMGB-Diff reduces data size by 64 times to use less memory, improves sampling efficiency by more than 10 times compared to other diffusion-based methods, and achieves optimal metrics, including SSIM, PSNR, COCO, and CV for various tissues. Hence, our MeMGB-Diff is a state-of-the-art (SOTA) method for 3D bias field correction.

Authors

Institutions

Publication Details

Journal
Medical Image Analysis
Published
2025-04-01
DOI
https://doi.org/10.1016/j.media.2025.103560
Citations
1
Primary Topic
Statistical Methods and Inference
Type
article
Field-Weighted Citation Impact
2.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MeMGB-Diff: Memory-Efficient Multivariate Gaussian Bias Diffusion Model for 3D bias field correction

Kuanquan Wang, Gongning Luo, Shuo Li, Xiangyu Li et al.
1 citations
Medical Image Analysis
Statistical Methods and Inference
2.63
article

MeMGB-Diff: Memory-Efficient Multivariate Gaussian Bias Diffusion Model for 3D bias field correction

Kuanquan Wang, Gongning Luo, Shuo Li, Xiangyu Li, Liang Dong, Wei Wang, Xingyu Qiu
article en
1 citations

Abstract

Bias fields inevitably degrade MRI that seriously interferes the diagnosis of physicians for accurate analysis, and removing it is a crucial image analysis task. Generative models (such as GANs) are used for bias field correction, and outperform traditional methods, however are hindered by the high cost of data annotation and instability during training. Recently, the diffusion-based methods have excelled over GANs in many applications, and they are powerful in removing noise from images, while the bias field can be regarded as a smooth noise. However, it is a challenge to directly apply to 3D bias field correction due to sampling inefficiency, the heavy computational demand, and implicit correction process. We propose a Memory-Efficient Multivariate Gaussian Bias Diffusion Model (MeMGB-Diff) that is an explicit, sampling, and memory both efficient diffusion model for 3D bias field correction without using clinical labels. MeMGB-Diff extends the diffusion models to multivariate Gaussian and models the bias field as a multivariate Gaussian variable, allowing direct diffusion and removal of the 3D bias fields without Gaussian noise. For memory efficiency, MeMGB-Diff performs diffusion model in smaller readable image domain at the expense of a negligible accuracy loss, based on the strong correlation among adjacent voxels of bias field. We also propose a loss function to mainly learn the intensity trend, which mainly causes the inhomogeneity of MRI, and effectively increases the correction accuracy. For comprehensive performance comparison, we propose a synthetic method for generating more varied bias fields during testing. Both quantitative and qualitative assessments on synthetic and clinical data confirm the high fidelity and uniform intensity of our results. MeMGB-Diff reduces data size by 64 times to use less memory, improves sampling efficiency by more than 10 times compared to other diffusion-based methods, and achieves optimal metrics, including SSIM, PSNR, COCO, and CV for various tissues. Hence, our MeMGB-Diff is a state-of-the-art (SOTA) method for 3D bias field correction.

Medical Image AnalysisVol. 102
Harbin Institute of Technology (CN), Case Western Reserve University (US)
Openalex Percentile: Top 13%
Statistical Methods and Inference
2.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.