Influence of Laser Cutting on the Functional Safety of Metallic Vascular Stents

A new method for the determination of missing data from scientific publications were presented on stent cutting lasers, using a combination of computational methods available from different sources in the literature. Some of the setting parameters for pulsed laser cutting are not independent of each other, which gives the possibility to determine some missing data in scientific articles: this way, data from different articles can be better evaluated, compared and experiments can be repeated, which is a useful basis for further development of a manufacturing technology. For this purpose, a new method was developed that allows the determination and calculation of the entire parameter system required for laser stent cutting. Finally, an evaluation system including weighting factors has been developed to quantify the defects of laser stent cutting, to classify the functional safety of the product, and to calculate the missing dimension that characterizes the cutting quality of stent manufacturing.

Authors

Institutions

Publication Details

Journal
Periodica Polytechnica Mechanical Engineering
Published
2025-04-01
DOI
https://doi.org/10.3311/ppme.40060
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Laser Cutting on the Functional Safety of Metallic Vascular Stents

Enikő Bitay, György Meszlényi
4 links
Periodica Polytechnica Mechanical Engineering
Coronary Interventions and Diagnostics
article

Influence of Laser Cutting on the Functional Safety of Metallic Vascular Stents

Enikő Bitay, György Meszlényi
article en

Abstract

A new method for the determination of missing data from scientific publications were presented on stent cutting lasers, using a combination of computational methods available from different sources in the literature. Some of the setting parameters for pulsed laser cutting are not independent of each other, which gives the possibility to determine some missing data in scientific articles: this way, data from different articles can be better evaluated, compared and experiments can be repeated, which is a useful basis for further development of a manufacturing technology. For this purpose, a new method was developed that allows the determination and calculation of the entire parameter system required for laser stent cutting. Finally, an evaluation system including weighting factors has been developed to quantify the defects of laser stent cutting, to classify the functional safety of the product, and to calculate the missing dimension that characterizes the cutting quality of stent manufacturing.

Periodica Polytechnica Mechanical EngineeringVol. 69(2)
Obuda University (HU), Sapientia Hungarian University of Transylvania (RO)
Openalex Percentile: Top 89%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of Laser Cutting on the Functional Safety of Metallic Vascular Stents — Enikő Bitay, György Meszlényi · Periodica Polytechnica Mechanical Engineering (2025) | TGRS Research Map | TGRS