Microfluidic-electrochemical sensor utilizing statistical modeling for enhanced nitrate detection in surface water towards environmental monitoring

The presence of nitrate (NO<sub>3</sub><sup>-</sup>) in surface water and groundwater used for potable supply needs to be closely monitored since in elevated amounts it can adversely affect aquatic life and human health by causing hypoxia and methemoglobinemia. Many of the existing EPA-certified sensors used for environmental monitoring are expensive, bulky, and labor-intensive. To address these concerns, we have successfully developed a low-cost microfluidic electrochemical impedimetric sensor, consisting of a nitrate-binding nickel complex within a polyaniline/carbon nanocomposite (Ni@Pani/C) enabling nitrate monitoring in field samples. Under optimized conditions, our sensor demonstrated a high sensitivity of 2.31 ± 0.09 Ω ppm<sup>-1</sup> cm<sup>-2</sup> across a wide nitrate concentration range (0.6-10 ppm). It also showed a desirable low detection limit of 0.015 ppm and a swift response time under 20 seconds. It maintained repeatability over a wide temperature range (5-65 °C) and exhibited consistent performance over an extended period (∼1 month). The sensor exhibited high specificity towards nitrate when tested against potential interferences (SO<sub>4</sub><sup>2-</sup>, C<sub>2</sub>H<sub>3</sub>O<sub>2</sub><sup>-</sup>, HCO<sub>3</sub><sup>-</sup>, NH<sub>4</sub><sup>+</sup>, Cl<sup>-</sup>) and showed good reproducibility for test water samples collected from various streams in Maryland, U.S.A. A statistical model was used to confirm the sensor's accuracy, which yielded a maximum standard deviation of ±0.6 ppm (absolute value). Our sensor was also benchmarked against a commercial SUNA device resulting in comparable performance.

Authors

Institutions

Publication Details

Journal
The Analyst
Published
2025-01-01
DOI
https://doi.org/10.1039/d5an00092k
Citations
5
Primary Topic
Water Quality Monitoring Technologies
Type
article
Field-Weighted Citation Impact
4.09
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microfluidic-electrochemical sensor utilizing statistical modeling for enhanced nitrate detection in surface water towards environmental monitoring

Michael McWilliams, Sanjeev Kumar Ujjain, Preety Ahuja, Claire Welty et al.
5 citations
The Analyst
Water Quality Monitoring Technologies
4.09
article

Microfluidic-electrochemical sensor utilizing statistical modeling for enhanced nitrate detection in surface water towards environmental monitoring

Michael McWilliams, Sanjeev Kumar Ujjain, Preety Ahuja, Claire Welty, Michael Tolosa, Douglas D. Frey, J.B. Lee, S. S. Mani, Govind Rao, Venkatesh Srinivasan, Md. Shajahan, Revati Kadolkar, Tithi Prajapati
article en
5 citations

Abstract

The presence of nitrate (NO<sub>3</sub><sup>-</sup>) in surface water and groundwater used for potable supply needs to be closely monitored since in elevated amounts it can adversely affect aquatic life and human health by causing hypoxia and methemoglobinemia. Many of the existing EPA-certified sensors used for environmental monitoring are expensive, bulky, and labor-intensive. To address these concerns, we have successfully developed a low-cost microfluidic electrochemical impedimetric sensor, consisting of a nitrate-binding nickel complex within a polyaniline/carbon nanocomposite (Ni@Pani/C) enabling nitrate monitoring in field samples. Under optimized conditions, our sensor demonstrated a high sensitivity of 2.31 ± 0.09 Ω ppm<sup>-1</sup> cm<sup>-2</sup> across a wide nitrate concentration range (0.6-10 ppm). It also showed a desirable low detection limit of 0.015 ppm and a swift response time under 20 seconds. It maintained repeatability over a wide temperature range (5-65 °C) and exhibited consistent performance over an extended period (∼1 month). The sensor exhibited high specificity towards nitrate when tested against potential interferences (SO<sub>4</sub><sup>2-</sup>, C<sub>2</sub>H<sub>3</sub>O<sub>2</sub><sup>-</sup>, HCO<sub>3</sub><sup>-</sup>, NH<sub>4</sub><sup>+</sup>, Cl<sup>-</sup>) and showed good reproducibility for test water samples collected from various streams in Maryland, U.S.A. A statistical model was used to confirm the sensor's accuracy, which yielded a maximum standard deviation of ±0.6 ppm (absolute value). Our sensor was also benchmarked against a commercial SUNA device resulting in comparable performance.

The AnalystVol. 150(10)
University of Maryland, Baltimore County (US)
Clean water and sanitation
Openalex Percentile: Top 7%
Water Quality Monitoring Technologies
4.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.