Preliminary findings from a retrospective comparative study on a novel hydrophobic C-loop monofocal intraocular lens

To investigate visual outcomes and optical performance of a new non-constant aberration aspheric monofocal intraocular lens (IOL). This study included consecutive patients who underwent phacoemulsification with implantation of either the CT LUCIA<sup>®</sup> 621P intraocular lens (Carl Zeiss Meditec AG, Jena, Germany; 32 eyes, 25 patients) or the Tecnis<sup>®</sup> ZCB00 intraocular lens (Johnson & Johnson Vision, Santa Ana, CA, USA; 38 eyes, 27 patients). Monocular uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), uncorrected intermediate visual acuity (UIVA), and objective optical quality were measured 3 months after surgery. The optical bench test measured the root mean square of the modulation transfer function (MTT<sub>RMS</sub>) of each IOL at defocus levels between +1.00 D and -2.50 D at intervals of 0.25 D at varying pupil sizes (2.0-5.0 mm) in 1.0 mm steps. There was no difference in UDVA, UNVA, and objective optical quality between CT LUCIA and ZCB00 groups. On the other hand, UIVA was higher in the CT LUCIA group (0.19 ± 0.12 logMAR) compared to the ZCB00 group (0.32 ± 0.05 logMAR; p < 0.001). For all tested pupil sizes, the MTF<sub>RMS</sub> values for both CT LUCIA and ZCB00 IOLs were similar across defocus ranges from +1.00 to -0.75 D. However, the CT LUCIA IOL consistently exhibited higher MTF<sub>RMS</sub> values than the ZCB00 IOL at defocus levels from -1.25 to - 2.50 D. The CT LUCIA IOL provides comparable distance visual acuity and optical quality to ZCB00 IOL, with superior performance at intermediate distances.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-04-01
DOI
https://doi.org/10.1038/s41598-025-89547-3
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preliminary findings from a retrospective comparative study on a novel hydrophobic C-loop monofocal intraocular lens

Hungwon Tchah, Jeongmin Kim, Youngsub Eom, Kyungmin Koh
Scientific Reports
Intraocular Surgery and Lenses
article

Preliminary findings from a retrospective comparative study on a novel hydrophobic C-loop monofocal intraocular lens

Hungwon Tchah, Jeongmin Kim, Youngsub Eom, Kyungmin Koh
article en

Abstract

To investigate visual outcomes and optical performance of a new non-constant aberration aspheric monofocal intraocular lens (IOL). This study included consecutive patients who underwent phacoemulsification with implantation of either the CT LUCIA<sup>®</sup> 621P intraocular lens (Carl Zeiss Meditec AG, Jena, Germany; 32 eyes, 25 patients) or the Tecnis<sup>®</sup> ZCB00 intraocular lens (Johnson & Johnson Vision, Santa Ana, CA, USA; 38 eyes, 27 patients). Monocular uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), uncorrected intermediate visual acuity (UIVA), and objective optical quality were measured 3 months after surgery. The optical bench test measured the root mean square of the modulation transfer function (MTT<sub>RMS</sub>) of each IOL at defocus levels between +1.00 D and -2.50 D at intervals of 0.25 D at varying pupil sizes (2.0-5.0 mm) in 1.0 mm steps. There was no difference in UDVA, UNVA, and objective optical quality between CT LUCIA and ZCB00 groups. On the other hand, UIVA was higher in the CT LUCIA group (0.19 ± 0.12 logMAR) compared to the ZCB00 group (0.32 ± 0.05 logMAR; p < 0.001). For all tested pupil sizes, the MTF<sub>RMS</sub> values for both CT LUCIA and ZCB00 IOLs were similar across defocus ranges from +1.00 to -0.75 D. However, the CT LUCIA IOL consistently exhibited higher MTF<sub>RMS</sub> values than the ZCB00 IOL at defocus levels from -1.25 to - 2.50 D. The CT LUCIA IOL provides comparable distance visual acuity and optical quality to ZCB00 IOL, with superior performance at intermediate distances.

Scientific ReportsVol. 15(1)
Konyang University (KR), Korea University (KR), Ansan University (KR), Kim's Eye Hospital (KR)
Zero hunger
Openalex Percentile: Top 89%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.