Some Features of Subcooled Dielectric Refrigerant R113 Boiling

The article presents the specific features of nucleate boiling of subcooled dielectric Freon R113 compared to water, revealed by generalizing existing and newly obtained experimental data. The experiments were carried out at atmospheric pressure in the ranges of subcooling to the saturation temperature Δtsub = 28–45°С and mass velocity ρw = 0–1500 kg/(m2 s). The main method for visualizing and registration flow characteristics was high-speed video filming with a frame rate of up to 50 kHz. The study revealed the absence of mechanisms underlying deactivation of nucleation sites and heat removal from the surface of a bubble observed during boiling of subcooled water at its growth stage via nonstationary thermal conductivity with a moving phase boundary. More favorable conditions for vapor phase accumulation in the core of a flow compared to water are demonstrated.

Authors

Institutions

Publication Details

Journal
High Temperature
Published
2024-10-01
DOI
https://doi.org/10.1134/s0018151x25700105
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Some Features of Subcooled Dielectric Refrigerant R113 Boiling

N Vasilev, S. N. Vavilov, Yu. A. Zeigarnik
High Temperature
Heat Transfer and Boiling Studies
article

Some Features of Subcooled Dielectric Refrigerant R113 Boiling

N Vasilev, S. N. Vavilov, Yu. A. Zeigarnik
article en

Abstract

The article presents the specific features of nucleate boiling of subcooled dielectric Freon R113 compared to water, revealed by generalizing existing and newly obtained experimental data. The experiments were carried out at atmospheric pressure in the ranges of subcooling to the saturation temperature Δtsub = 28–45°С and mass velocity ρw = 0–1500 kg/(m2 s). The main method for visualizing and registration flow characteristics was high-speed video filming with a frame rate of up to 50 kHz. The study revealed the absence of mechanisms underlying deactivation of nucleation sites and heat removal from the surface of a bubble observed during boiling of subcooled water at its growth stage via nonstationary thermal conductivity with a moving phase boundary. More favorable conditions for vapor phase accumulation in the core of a flow compared to water are demonstrated.

High TemperatureVol. 62(5)
Joint Institute for High Temperatures (RU)
Affordable and clean energy
Openalex Percentile: Top 71%
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Some Features of Subcooled Dielectric Refrigerant R113 Boiling — N Vasilev, S. N. Vavilov, et al. · High Temperature (2024) | TGRS Research Map | TGRS