Automated mitochondrial oxygen consumption (mitoVO2) analysis via a bi-directional long short-term memory neural network

Monitoring in vivo mitochondrial oxygen tension (mitoPO<sub>2</sub>) enables the measurement of mitochondrial oxygen consumption (mitoVO<sub>2</sub>), providing deeper insights into the skin's mitochondrial environment. However, current mitoVO<sub>2</sub> analysis often relies on manual identification of start and end points, which introduces substantial inter-user variability. Addressing this limitation is crucial for broader adoption, comparability, and reproducibility across research groups. Therefore, the aim of this study was to develop a neural network-based software that automatically analyzes mitoVO<sub>2</sub>. A Bi-directional Long Short-Term Memory neural network was trained on 125 mitoPO<sub>2</sub> measurement sequences and optimized through Bayesian optimization. It identifies start points and measurement periods, then applies a modified Michaelis-Menten fit to calculate mitoVO<sub>2</sub>. This framework, embedded in automated software, was validated against the consensus of 3 raters. Bayesian optimization yielded an overall network performance of 94.2% on the test set. The neural network identified 91% of mitoVO<sub>2</sub> start points within a ± 5-sample range of the manual consensus. Mean mitoVO<sub>2</sub> values for the consensus and software were 6.56 and 6.63 mmHg s<sup>- 1</sup>, respectively, corresponding to a bias of -0.057 mmHg s<sup>- 1</sup>. Multiple runs of the network on the same dataset produced identical results, confirming consistency and eliminating inter-user variability. The developed neural network-based software automatically and consistently analyzes mitoVO<sub>2</sub> measurements, substantially reducing reliance on subjective judgments. By enabling a standardized approach to mitoVO<sub>2</sub> analysis, this tool improves data comparability and reproducibility across research settings. Future work will focus on further refining precision and extending functionality through multi-center collaborations.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Monitoring and Computing
Published
2025-03-30
DOI
https://doi.org/10.1007/s10877-025-01291-1
Citations
3
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
3.49
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated mitochondrial oxygen consumption (mitoVO2) analysis via a bi-directional long short-term memory neural network

J. R. Behr, Lucia W. J. M. Streng, Egbert G. Mik, Floor A. Harms et al.
3 citations
Journal of Clinical Monitoring and Computing
Thermoregulation and physiological responses
3.49
article

Automated mitochondrial oxygen consumption (mitoVO2) analysis via a bi-directional long short-term memory neural network

J. R. Behr, Lucia W. J. M. Streng, Egbert G. Mik, Floor A. Harms, Calvin J. de Wijs, M. E. van der Graaf
article en
3 citations

Abstract

Monitoring in vivo mitochondrial oxygen tension (mitoPO<sub>2</sub>) enables the measurement of mitochondrial oxygen consumption (mitoVO<sub>2</sub>), providing deeper insights into the skin's mitochondrial environment. However, current mitoVO<sub>2</sub> analysis often relies on manual identification of start and end points, which introduces substantial inter-user variability. Addressing this limitation is crucial for broader adoption, comparability, and reproducibility across research groups. Therefore, the aim of this study was to develop a neural network-based software that automatically analyzes mitoVO<sub>2</sub>. A Bi-directional Long Short-Term Memory neural network was trained on 125 mitoPO<sub>2</sub> measurement sequences and optimized through Bayesian optimization. It identifies start points and measurement periods, then applies a modified Michaelis-Menten fit to calculate mitoVO<sub>2</sub>. This framework, embedded in automated software, was validated against the consensus of 3 raters. Bayesian optimization yielded an overall network performance of 94.2% on the test set. The neural network identified 91% of mitoVO<sub>2</sub> start points within a ± 5-sample range of the manual consensus. Mean mitoVO<sub>2</sub> values for the consensus and software were 6.56 and 6.63 mmHg s<sup>- 1</sup>, respectively, corresponding to a bias of -0.057 mmHg s<sup>- 1</sup>. Multiple runs of the network on the same dataset produced identical results, confirming consistency and eliminating inter-user variability. The developed neural network-based software automatically and consistently analyzes mitoVO<sub>2</sub> measurements, substantially reducing reliance on subjective judgments. By enabling a standardized approach to mitoVO<sub>2</sub> analysis, this tool improves data comparability and reproducibility across research settings. Future work will focus on further refining precision and extending functionality through multi-center collaborations.

Journal of Clinical Monitoring and ComputingVol. 39(5)
Erasmus MC (NL), Delft University of Technology (NL)
Openalex Percentile: Top 8%
Thermoregulation and physiological responses
3.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.