Performance evaluation and correction of Al <sub>2</sub>O <sub>3</sub> and YSZ-doped In <sub>2</sub>O <sub>3</sub>/In <sub>2</sub>O <sub>3</sub> multilayer heterogeneous thin-film thermocouples up to 1850 °C

The combustion chamber temperature of the new generation aircraft engines can reach an ultra-high temperature of 1800 °C, making temperature monitoring of key components crucial. Thin-film thermocouples (TFTCs) are highly sensitive and have rapid response time; however, their upper temperature limit remains below 1800 °C. This study proposes an ultra-high temperature film thermocouple, enhanced by yttria-stabilized zirconia (YSZ) for positive film, indium oxide (In<sub>2</sub>O<sub>3</sub>) for negative film, aluminium oxide (Al<sub>2</sub>O<sub>3</sub>) for protect film. The thermocouple is designed based on temperature measurement principles, First-principles, and simulations, and it is manufactured via screen-printing. The results indicate that the maximum working temperature is 1850 ℃. In experiments with different doping ratios at 1800 ℃, the thermocouple achieves a maximum temperature electromotive force (TEMF) of 258.5 mV and a maximum Seebeck coefficient of 180.9 μV/°C, with an In<sub>2</sub>O<sub>3</sub>:YSZ92(ZrO<sub>2</sub>:Y<sub>2</sub>O<sub>3 </sub>= 92:8 wt%) ratio of 9:1 wt%. Using the lumped heat capacity method, the response time is measured at 2.8 ms, demonstrating good dynamic response characteristics. The film thermocouple is successfully utilized to measure the gas temperature of 1090 °C at the outlet of air turbine rocket engine, confirming its high-temperature operational capability. To improve the repeatability of the TFTCs without affecting their thermoelectric outputs, a CNN-LSTM-attention neural network is implemented to mitigate repeatability errors, achieving a high repeatability of 99.53%. Additionally, the compensated temperature data are compared with those obtained from a standard B-type thermocouple, showing a full-scale error of ±0.73% FS. This study provides a feasible solution for ultra-high temperature measurements.

Authors

Publication Details

Journal
Journal of Advanced Ceramics
Published
2025-04-01
DOI
https://doi.org/10.26599/jac.2025.9221071
Citations
3
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
2.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance evaluation and correction of Al 2O 3 and YSZ-doped In 2O 3/In 2O 3 multilayer heterogeneous thin-film thermocouples up to 1850 °C

Weixuan Jing, Meng Wang, Zhongkai Zhang, D.F. Liu et al.
3 citations
Journal of Advanced Ceramics
Advanced Sensor Technologies Research
2.02
article

Performance evaluation and correction of Al 2O 3 and YSZ-doped In 2O 3/In 2O 3 multilayer heterogeneous thin-film thermocouples up to 1850 °C

Weixuan Jing, Meng Wang, Zhongkai Zhang, D.F. Liu, Jiaming Lei, Bian Tian, Bo Li, Zhaojun Liu, Le Li, Yong Xia
article en
3 citations

Abstract

The combustion chamber temperature of the new generation aircraft engines can reach an ultra-high temperature of 1800 °C, making temperature monitoring of key components crucial. Thin-film thermocouples (TFTCs) are highly sensitive and have rapid response time; however, their upper temperature limit remains below 1800 °C. This study proposes an ultra-high temperature film thermocouple, enhanced by yttria-stabilized zirconia (YSZ) for positive film, indium oxide (In<sub>2</sub>O<sub>3</sub>) for negative film, aluminium oxide (Al<sub>2</sub>O<sub>3</sub>) for protect film. The thermocouple is designed based on temperature measurement principles, First-principles, and simulations, and it is manufactured via screen-printing. The results indicate that the maximum working temperature is 1850 ℃. In experiments with different doping ratios at 1800 ℃, the thermocouple achieves a maximum temperature electromotive force (TEMF) of 258.5 mV and a maximum Seebeck coefficient of 180.9 μV/°C, with an In<sub>2</sub>O<sub>3</sub>:YSZ92(ZrO<sub>2</sub>:Y<sub>2</sub>O<sub>3 </sub>= 92:8 wt%) ratio of 9:1 wt%. Using the lumped heat capacity method, the response time is measured at 2.8 ms, demonstrating good dynamic response characteristics. The film thermocouple is successfully utilized to measure the gas temperature of 1090 °C at the outlet of air turbine rocket engine, confirming its high-temperature operational capability. To improve the repeatability of the TFTCs without affecting their thermoelectric outputs, a CNN-LSTM-attention neural network is implemented to mitigate repeatability errors, achieving a high repeatability of 99.53%. Additionally, the compensated temperature data are compared with those obtained from a standard B-type thermocouple, showing a full-scale error of ±0.73% FS. This study provides a feasible solution for ultra-high temperature measurements.

Journal of Advanced CeramicsVol. 14(5)
Openalex Percentile: Top 15%
Advanced Sensor Technologies Research
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.