Propafenone Bioanalytical Method Development And Validation Using RP-UPLC Chromatographic Method Following ICH M10 Guidelines

A simple, Accurate, precise method was developed for the estimation of Propafenone in Rabbit plasma was developed and validated. By using protein precipitation technique, the sample preparation was prepared. Chromatogram was run through ACQUITY UPLC HSS C18 Column, 1.8 µm, 2.1 mm X 100 mm, Mobile phase containing Buffer DiSodium Hydrogen Phosphate: Acetonitrile taken in the ratio 70:30 was pumped through column at a flow rate of 0.3ml/min. Buffer used Na2HPO4.in this method was buffer. For the separation of Propafenone Internal Standard [IS] used is Vildagliptin. The Temperature was maintained at 30°C. Optimized wavelength selected was 248nm.  Retention time of Propafenone and Internal Standard were found to be 1.273 min and 0.972 min. The standard curve was linear (R2 >0.995) over the concentration range of 15-600 ng/ml. All the analytical validation parameters were determined as per ICH guidelines the bioanalytical method developed approach was selective, robust, and reliable, as accuracy, precision, recovery, and other validation parameters were all within the recommendations' limitations. The peaks produced for the drug of interest and the internal standard were well separated from one another without any plasma interferences, and the peaks were symmetrical with an adequate tailing factor.

Authors

Publication Details

Journal
African Journal of Biomedical Research
Published
2024-12-30
DOI
https://doi.org/10.53555/ajbr.v27i4s.7250
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Propafenone Bioanalytical Method Development And Validation Using RP-UPLC Chromatographic Method Following ICH M10 Guidelines

Tanniru Rajeswari
African Journal of Biomedical Research
Analytical Chemistry and Chromatography
article

Propafenone Bioanalytical Method Development And Validation Using RP-UPLC Chromatographic Method Following ICH M10 Guidelines

Tanniru Rajeswari
article en

Abstract

A simple, Accurate, precise method was developed for the estimation of Propafenone in Rabbit plasma was developed and validated. By using protein precipitation technique, the sample preparation was prepared. Chromatogram was run through ACQUITY UPLC HSS C18 Column, 1.8 µm, 2.1 mm X 100 mm, Mobile phase containing Buffer DiSodium Hydrogen Phosphate: Acetonitrile taken in the ratio 70:30 was pumped through column at a flow rate of 0.3ml/min. Buffer used Na2HPO4.in this method was buffer. For the separation of Propafenone Internal Standard [IS] used is Vildagliptin. The Temperature was maintained at 30°C. Optimized wavelength selected was 248nm.  Retention time of Propafenone and Internal Standard were found to be 1.273 min and 0.972 min. The standard curve was linear (R2 >0.995) over the concentration range of 15-600 ng/ml. All the analytical validation parameters were determined as per ICH guidelines the bioanalytical method developed approach was selective, robust, and reliable, as accuracy, precision, recovery, and other validation parameters were all within the recommendations' limitations. The peaks produced for the drug of interest and the internal standard were well separated from one another without any plasma interferences, and the peaks were symmetrical with an adequate tailing factor.

African Journal of Biomedical Research
Openalex Percentile: Top 79%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Propafenone Bioanalytical Method Development And Validation Using RP-UPLC Chromatographic Method Following ICH M10 Guidelines — Tanniru Rajeswari · African Journal of Biomedical Research (2024) | TGRS Research Map | TGRS