Chemical and surface modification in graphene oxide for optimum CO<sub>2</sub> gas sensing performance

Abstract The level of CO 2 gas sensing is very crucial for applications such as medical and air quality monitoring. The conventional metal oxide-based CO 2 sensors are sensitive but they need additional excitation like high temperature to be operated at room temperature. In this study, the effect of reduction time on the surface functional groups of the graphene-based sensing layer is investigated to achieve high performance of CO 2 gas sensors to be operated at room temperature. Five reduction times (20, 30, 40, 50, 60 min) are examined to synthesize reduced graphene oxide (rGO) from GO precursor material using green reducing agent ascorbic acid. The structural and morphological properties of rGO-based ArGO samples are investigated using FTIR, Raman, and SEM characterization techniques exhibiting the layered, wrinkled structure with apparent folds on the ArGO thin film surface. The highest and the lowest number of oxygen functional groups are shown by the ArGO20 and ArGO60 thin films, respectively. The electrical characterization presents the highest sheet resistance of 786 KΩ sq −1 and the lowest sheet resistance of 103 KΩ sq −1 for ArGO20 and ArGO60 thin films, respectively. Five sensors are fabricated following the reduction time to detect the CO 2 gas at room temperature. Among them, the ArGO40 sensor demonstrated optimum sensing response towards CO 2 gas with high sensitivity, repeatability, selectivity, and long-term stability, revealing that the reduction time of 40 min is optimum to synthesize functionalized graphene sensing material for CO 2 detection.

Authors

Institutions

Publication Details

Journal
Nano Express
Published
2025-03-31
DOI
https://doi.org/10.1088/2632-959x/adc758
Citations
7
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
5.11
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Chemical and surface modification in graphene oxide for optimum CO2 gas sensing performance

Vipin Kumar, Monika Gupta, Pradeep Kumar, Yogendra Kumar Mishra et al.
7 citations
Nano Express
Gas Sensing Nanomaterials and Sensors
5.11
article

Chemical and surface modification in graphene oxide for optimum CO2 gas sensing performance

Vipin Kumar, Monika Gupta, Pradeep Kumar, Yogendra Kumar Mishra, Huzein Fahmi Hawari
article en
7 citations

Abstract

Abstract The level of CO 2 gas sensing is very crucial for applications such as medical and air quality monitoring. The conventional metal oxide-based CO 2 sensors are sensitive but they need additional excitation like high temperature to be operated at room temperature. In this study, the effect of reduction time on the surface functional groups of the graphene-based sensing layer is investigated to achieve high performance of CO 2 gas sensors to be operated at room temperature. Five reduction times (20, 30, 40, 50, 60 min) are examined to synthesize reduced graphene oxide (rGO) from GO precursor material using green reducing agent ascorbic acid. The structural and morphological properties of rGO-based ArGO samples are investigated using FTIR, Raman, and SEM characterization techniques exhibiting the layered, wrinkled structure with apparent folds on the ArGO thin film surface. The highest and the lowest number of oxygen functional groups are shown by the ArGO20 and ArGO60 thin films, respectively. The electrical characterization presents the highest sheet resistance of 786 KΩ sq −1 and the lowest sheet resistance of 103 KΩ sq −1 for ArGO20 and ArGO60 thin films, respectively. Five sensors are fabricated following the reduction time to detect the CO 2 gas at room temperature. Among them, the ArGO40 sensor demonstrated optimum sensing response towards CO 2 gas with high sensitivity, repeatability, selectivity, and long-term stability, revealing that the reduction time of 40 min is optimum to synthesize functionalized graphene sensing material for CO 2 detection.

Nano ExpressVol. 6(2)
University of Southern Denmark (DK), Universiti Teknologi Petronas (MY), Hospital Terrassa (ES), Universiti Malaysia Perlis (MY)
Openalex Percentile: Top 5%
Gas Sensing Nanomaterials and Sensors
5.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.