Impact of Thermal and Electrical Dissimilarities on Battery Module Aging

<div class="section abstract"><div class="htmlview paragraph">Battery cell aging and loss of capacity are some of the many challenges facing the widespread implementation of electrification in mobility. One of the factors contributing to cell aging is the dissimilarities of individual cells connected in a module. This paper reports the results of several aging experiments using a mini-module consisting of seven 5 Ah 21700 lithium-ion battery cells connected in parallel. The aging cycle comprised a constant current-constant voltage charge cycle at a 0.7C C-rate, followed by a 0.2C constant current discharge, spanning the useful voltage range from minimum to maximum according to the cell manufacturer. Charge and discharge events were separated by one-hour rest periods and were repeated for four weeks. Weekly reference performance tests were executed to measure static capacity, pulse power capability and resistance at different states of charge. All diagnostics were normalized with respect to their starting numbers to achieve a percentage change over time. Both electrical and thermal dissimilarities were considered by initial cell selection or adjusting the thermal boundary conditions, respectively. The latter was achieved by contrasting air cooling with direct liquid immersion cooling which prevented temperature spikes and ensured more uniform temperature distribution between the cells. For well-clustered cells, the use of immersion cooling reduced the capacity fade noticeably when compared to air cooling. However, when cells are not well clustered, the impact of electrical dissimilarities overshadowed the thermal benefits. Poor cell clustering resulted in a lower discharge resistance increase which itself reflected as smaller changes of the pulse power fade. The results highlighted the importance of cell selection and clustering during research and when building packs for final application and reinforced the benefits of good thermal management. The work did not fully explore the benefits of immersion cooling due to the moderate C-rates used.</div></div>

Authors

Institutions

Publication Details

Journal
SAE technical papers on CD-ROM/SAE technical paper series
Published
2025-04-01
DOI
https://doi.org/10.4271/2025-01-8173
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Thermal and Electrical Dissimilarities on Battery Module Aging

Swapnil S. Salvi, Daniel Juarez Robles, André Swarts
SAE technical papers on CD-ROM/SAE technical paper series
Advanced Battery Technologies Research
article

Impact of Thermal and Electrical Dissimilarities on Battery Module Aging

Swapnil S. Salvi, Daniel Juarez Robles, André Swarts
article en

Abstract

<div class="section abstract"><div class="htmlview paragraph">Battery cell aging and loss of capacity are some of the many challenges facing the widespread implementation of electrification in mobility. One of the factors contributing to cell aging is the dissimilarities of individual cells connected in a module. This paper reports the results of several aging experiments using a mini-module consisting of seven 5 Ah 21700 lithium-ion battery cells connected in parallel. The aging cycle comprised a constant current-constant voltage charge cycle at a 0.7C C-rate, followed by a 0.2C constant current discharge, spanning the useful voltage range from minimum to maximum according to the cell manufacturer. Charge and discharge events were separated by one-hour rest periods and were repeated for four weeks. Weekly reference performance tests were executed to measure static capacity, pulse power capability and resistance at different states of charge. All diagnostics were normalized with respect to their starting numbers to achieve a percentage change over time. Both electrical and thermal dissimilarities were considered by initial cell selection or adjusting the thermal boundary conditions, respectively. The latter was achieved by contrasting air cooling with direct liquid immersion cooling which prevented temperature spikes and ensured more uniform temperature distribution between the cells. For well-clustered cells, the use of immersion cooling reduced the capacity fade noticeably when compared to air cooling. However, when cells are not well clustered, the impact of electrical dissimilarities overshadowed the thermal benefits. Poor cell clustering resulted in a lower discharge resistance increase which itself reflected as smaller changes of the pulse power fade. The results highlighted the importance of cell selection and clustering during research and when building packs for final application and reinforced the benefits of good thermal management. The work did not fully explore the benefits of immersion cooling due to the moderate C-rates used.</div></div>

SAE technical papers on CD-ROM/SAE technical paper seriesVol. 1
Southwest Research Institute (US)
Openalex Percentile: Top 94%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.