Investigation of Impedance Evolution for Lithium Plating Detection during Multi-Stage Constant Current Fast Charging of Lithium-Ion Batteries

<div class="section abstract"><div class="htmlview paragraph">aThe lengthy charging time of lithium-ion batteries for electric vehicles (EVs) significantly affect their acceptance. Reducing charging time requires high-power fast charging. However, such fast charging can trigger various side reactions, leading to safety and durability issues. Among these, lithium plating is a major concern as it can reduce battery capacity and potentially cause internal short circuits or even thermal runaway. Currently, multi-stage constant current charging (MCCC) protocols are widely adopted. However, the difficulty in effectively detecting lithium plating during the MCCC process significantly limits the charging power. Therefore, it is urgent to explore a method to detect lithium plating during the MCCC process. In this study, the impedance evolution during the MCCC procedure was first investigated. Then a method based on the impedance variation patterns was proposed to detect lithium plating. Besides, the reason for the behavior of impedance changes was further investigated. Specifically, the experimental results suggest that when lithium plating occurs, it leads to an abnormal decrease in the 1 Hz impedance. This phenomenon is observed across different temperatures and charging rates during the MCCC process. By monitoring the trend of abnormal accelerated decrease in 1 Hz impedance, lithium plating can be accurately detected before it significantly deteriorates. Furthermore, this method was integrated into the battery management system (BMS), enabling a closed-loop MCCC protocol, which provides a method that can be used to prevent irreversible lithium plating while shortening charging time. The impedance-based method provides a feasible solution for non-destructive online lithium plating detection during the MCCC procedure, offering a practical approach for fast charging of EVs.</div></div>

Authors

Institutions

Publication Details

Journal
SAE technical papers on CD-ROM/SAE technical paper series
Published
2025-04-01
DOI
https://doi.org/10.4271/2025-01-8124
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Impedance Evolution for Lithium Plating Detection during Multi-Stage Constant Current Fast Charging of Lithium-Ion Batteries

Haifeng Dai, Hang Wu, Xuezhe Wei, Xueyuan Wang et al.
SAE technical papers on CD-ROM/SAE technical paper series
Advanced Battery Technologies Research
article

Investigation of Impedance Evolution for Lithium Plating Detection during Multi-Stage Constant Current Fast Charging of Lithium-Ion Batteries

Haifeng Dai, Hang Wu, Xuezhe Wei, Xueyuan Wang, Yudong Shen
article en

Abstract

<div class="section abstract"><div class="htmlview paragraph">aThe lengthy charging time of lithium-ion batteries for electric vehicles (EVs) significantly affect their acceptance. Reducing charging time requires high-power fast charging. However, such fast charging can trigger various side reactions, leading to safety and durability issues. Among these, lithium plating is a major concern as it can reduce battery capacity and potentially cause internal short circuits or even thermal runaway. Currently, multi-stage constant current charging (MCCC) protocols are widely adopted. However, the difficulty in effectively detecting lithium plating during the MCCC process significantly limits the charging power. Therefore, it is urgent to explore a method to detect lithium plating during the MCCC process. In this study, the impedance evolution during the MCCC procedure was first investigated. Then a method based on the impedance variation patterns was proposed to detect lithium plating. Besides, the reason for the behavior of impedance changes was further investigated. Specifically, the experimental results suggest that when lithium plating occurs, it leads to an abnormal decrease in the 1 Hz impedance. This phenomenon is observed across different temperatures and charging rates during the MCCC process. By monitoring the trend of abnormal accelerated decrease in 1 Hz impedance, lithium plating can be accurately detected before it significantly deteriorates. Furthermore, this method was integrated into the battery management system (BMS), enabling a closed-loop MCCC protocol, which provides a method that can be used to prevent irreversible lithium plating while shortening charging time. The impedance-based method provides a feasible solution for non-destructive online lithium plating detection during the MCCC procedure, offering a practical approach for fast charging of EVs.</div></div>

SAE technical papers on CD-ROM/SAE technical paper seriesVol. 1
Tongji University (CN)
Openalex Percentile: Top 94%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.