Research on Boost Control for Powertrain Control System

<div class="section abstract"><div class="htmlview paragraph">In the domain of new energy vehicles, the role of the bidirectional DC/DC converter holds great significance. Based on the two-phase interleaved parallel BOOST topology, this paper adopts the approach of combining the double-loop PI controller with the feedforward control algorithm respectively from the aspects of following the target voltage and response speed, and conducts research on the performance of the DC/DC converter in BOOST mode in terms of output voltage overshoot, steady-state error, and system adjustment time. The test results fully validate the feasibility and effectiveness of the design scheme. The test results indicate that the double-loop PI control + feedforward control method accelerates the circuit response speed, reduces the steady-state error, and significantly reduces the input/output current ripple, fully verifying the feasibility and effectiveness of the control method. Furthermore, regarding the overvoltage issue that occurs after a large accelerator pedal in the hybrid vehicle with BOOST, the influence of post-overvoltage processing is analyzed emphatically, and the calibration strategy for the overvoltage problem is introduced. Among them, the fault handling mechanism for the BOOST software output overvoltage is that the BOOST upper and lower bridge software is blocked, and the P1/P2 software performs zero torque processing after receiving the BOOST software output overvoltage signal; after waiting for the BOOST fault to recover and enter the working mode, P1/P2 can operate in accordance with the current available power. Optimization calibration and real vehicle tests have been carried out. The test results demonstrate that the overvoltage problem can be effectively addressed by the adopted calibration method, and the drivability has been significantly enhanced.</div></div>

Authors

Institutions

Publication Details

Journal
SAE technical papers on CD-ROM/SAE technical paper series
Published
2025-03-31
DOI
https://doi.org/10.4271/2025-01-8514
Citations
1
Primary Topic
Real-time simulation and control systems
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Boost Control for Powertrain Control System

Botao Zuo, Zhengxing Dai, Weishan Huang, Yiqiang Liu et al.
1 citations
SAE technical papers on CD-ROM/SAE technical paper series
Real-time simulation and control systems
1.21
article

Research on Boost Control for Powertrain Control System

Botao Zuo, Zhengxing Dai, Weishan Huang, Yiqiang Liu, Junchao Jing
article en
1 citations

Abstract

<div class="section abstract"><div class="htmlview paragraph">In the domain of new energy vehicles, the role of the bidirectional DC/DC converter holds great significance. Based on the two-phase interleaved parallel BOOST topology, this paper adopts the approach of combining the double-loop PI controller with the feedforward control algorithm respectively from the aspects of following the target voltage and response speed, and conducts research on the performance of the DC/DC converter in BOOST mode in terms of output voltage overshoot, steady-state error, and system adjustment time. The test results fully validate the feasibility and effectiveness of the design scheme. The test results indicate that the double-loop PI control + feedforward control method accelerates the circuit response speed, reduces the steady-state error, and significantly reduces the input/output current ripple, fully verifying the feasibility and effectiveness of the control method. Furthermore, regarding the overvoltage issue that occurs after a large accelerator pedal in the hybrid vehicle with BOOST, the influence of post-overvoltage processing is analyzed emphatically, and the calibration strategy for the overvoltage problem is introduced. Among them, the fault handling mechanism for the BOOST software output overvoltage is that the BOOST upper and lower bridge software is blocked, and the P1/P2 software performs zero torque processing after receiving the BOOST software output overvoltage signal; after waiting for the BOOST fault to recover and enter the working mode, P1/P2 can operate in accordance with the current available power. Optimization calibration and real vehicle tests have been carried out. The test results demonstrate that the overvoltage problem can be effectively addressed by the adopted calibration method, and the drivability has been significantly enhanced.</div></div>

SAE technical papers on CD-ROM/SAE technical paper seriesVol. 1
Geely (China) (CN)
Openalex Percentile: Top 23%
Real-time simulation and control systems
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on Boost Control for Powertrain Control System — Botao Zuo, Zhengxing Dai, et al. · SAE technical papers on CD-ROM/SAE technical paper series (2025) | TGRS Research Map | TGRS