Impact of Thermal Gradients on Calorimetry Testing of Battery Cells

<div class="section abstract"><div class="htmlview paragraph">Detailed modeling of battery thermal runaway and propagation often requires a source term that represents the chemical heat release of the cell as a function of temperature. The shape of this heat release trend typically comes from cell testing data. Accelerating rate calorimetry (ARC) tests provide concise information on cell self-heating, since the cell is kept nearly isothermal and adiabatic. Also, compared to differential scanning calorimetry (DSC) tests of battery component materials, it contains all interactions between components. Converting the temperature rise rate data to heat release rate is theoretically very simple, only requiring the heat capacity of the cell. Practically, however, careful analysis is required to avoid artifacts arising from limitations of the test setup. This study uses a simple one-dimensional transient heat transfer model to illustrate the runaway process inside a cell and describe two error sources present in many ARC tests. As the cell temperature increases, temperature gradients tend to get amplified, which transitions into a reaction front. At that point, the isothermal assumption has broken down. When the reaction front reaches the thermocouple measuring the cell temperature, it is registered as a sudden jump in temperature rise rate that is observed in many tests. In addition, any fixturing, especially compression plates often used for pouch cells, is shown to act as a heat sink, which interferes with the adiabatic assumption and introduces temperature gradients. The impact of these errors on the predicted heat release rate is described, as well as potential countermeasures.</div></div>

Authors

Publication Details

Journal
SAE technical papers on CD-ROM/SAE technical paper series
Published
2025-03-31
DOI
https://doi.org/10.4271/2025-01-8175
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Thermal Gradients on Calorimetry Testing of Battery Cells

B. Petersen, Brad Vanderwege
2 links
SAE technical papers on CD-ROM/SAE technical paper series
Advanced Battery Technologies Research
article

Impact of Thermal Gradients on Calorimetry Testing of Battery Cells

B. Petersen, Brad Vanderwege
article en

Abstract

<div class="section abstract"><div class="htmlview paragraph">Detailed modeling of battery thermal runaway and propagation often requires a source term that represents the chemical heat release of the cell as a function of temperature. The shape of this heat release trend typically comes from cell testing data. Accelerating rate calorimetry (ARC) tests provide concise information on cell self-heating, since the cell is kept nearly isothermal and adiabatic. Also, compared to differential scanning calorimetry (DSC) tests of battery component materials, it contains all interactions between components. Converting the temperature rise rate data to heat release rate is theoretically very simple, only requiring the heat capacity of the cell. Practically, however, careful analysis is required to avoid artifacts arising from limitations of the test setup. This study uses a simple one-dimensional transient heat transfer model to illustrate the runaway process inside a cell and describe two error sources present in many ARC tests. As the cell temperature increases, temperature gradients tend to get amplified, which transitions into a reaction front. At that point, the isothermal assumption has broken down. When the reaction front reaches the thermocouple measuring the cell temperature, it is registered as a sudden jump in temperature rise rate that is observed in many tests. In addition, any fixturing, especially compression plates often used for pouch cells, is shown to act as a heat sink, which interferes with the adiabatic assumption and introduces temperature gradients. The impact of these errors on the predicted heat release rate is described, as well as potential countermeasures.</div></div>

SAE technical papers on CD-ROM/SAE technical paper seriesVol. 1
Openalex Percentile: Top 94%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of Thermal Gradients on Calorimetry Testing of Battery Cells — B. Petersen, Brad Vanderwege · SAE technical papers on CD-ROM/SAE technical paper series (2025) | TGRS Research Map | TGRS