Liquid Viscosity Decoupling Measurement Based on U-Shaped Tungsten Wire Sensor

<div class="section abstract"><div class="htmlview paragraph">In this paper, based on the cylindrical flow theory of incompressible viscous fluids and the equivalent circuit model of resonant sensing elements, a theoretical model for the measurement of liquid viscosity with a U-Shaped tungsten wire resonance sensor was established. This model can measure the liquid viscosity independently without liquid density or coupled detection of liquid density. The experimental results show that the decoupling of liquid viscosity and its density can be achieved at Re<1. The liquid viscosity is strongly linear with the resonant conductance. The viscosity measurement error is less than 7.24% in the viscosity range of 7.235cP to 85.2cP.</div></div>

Authors

Institutions

Publication Details

Journal
SAE technical papers on CD-ROM/SAE technical paper series
Published
2025-03-31
DOI
https://doi.org/10.4271/2025-01-8460
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Liquid Viscosity Decoupling Measurement Based on U-Shaped Tungsten Wire Sensor

Baoguo Shan, Jianguo Yang, Yitao Shen, Dehong Wu
SAE technical papers on CD-ROM/SAE technical paper series
Analytical Chemistry and Sensors
article

Liquid Viscosity Decoupling Measurement Based on U-Shaped Tungsten Wire Sensor

Baoguo Shan, Jianguo Yang, Yitao Shen, Dehong Wu
article en

Abstract

<div class="section abstract"><div class="htmlview paragraph">In this paper, based on the cylindrical flow theory of incompressible viscous fluids and the equivalent circuit model of resonant sensing elements, a theoretical model for the measurement of liquid viscosity with a U-Shaped tungsten wire resonance sensor was established. This model can measure the liquid viscosity independently without liquid density or coupled detection of liquid density. The experimental results show that the decoupling of liquid viscosity and its density can be achieved at Re<1. The liquid viscosity is strongly linear with the resonant conductance. The viscosity measurement error is less than 7.24% in the viscosity range of 7.235cP to 85.2cP.</div></div>

SAE technical papers on CD-ROM/SAE technical paper seriesVol. 1
Harbin Institute of Technology (CN)
Openalex Percentile: Top 91%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Liquid Viscosity Decoupling Measurement Based on U-Shaped Tungsten Wire Sensor — Baoguo Shan, Jianguo Yang, et al. · SAE technical papers on CD-ROM/SAE technical paper series (2025) | TGRS Research Map | TGRS