Reduced Order Model for Viscosity and Mass Density Sensing by A U-Shaped Wire

<div class="section abstract"><div class="htmlview paragraph">This paper focuses on the basic principle of measuring viscosity and density with U-shaped tungsten wire sensor, and develops a model for measuring liquid viscosity and density with the help of oscillating ball model. Firstly, the working mechanism of the wire resonator is deeply analyzed. Then, by reducing the order of the fluid dynamic function, a simplified model is established for measuring the viscosity and density of liquid with U-shaped tungsten resonator. The experimental results show that the maximum error of viscosity is 7.22% and the average error is 2.81% when the viscosity ranges from 4.526mPa.s to 62.01mPa.s. In the range of 0.8486g/cm<sup>3</sup> to 0.8711g/cm<sup>3</sup>, the maximum density error is 7.00% and the average density error is 1.89%. In summary, the simplified model proposed in this paper can accurately measure the viscosity and density of liquids.</div></div>

Authors

Institutions

Publication Details

Journal
SAE technical papers on CD-ROM/SAE technical paper series
Published
2025-03-31
DOI
https://doi.org/10.4271/2025-01-8472
Primary Topic
Acoustic Wave Resonator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reduced Order Model for Viscosity and Mass Density Sensing by A U-Shaped Wire

Zhaoying Zhang, Jianguo Yang, Yajuan Zhao, Baoen Shan et al.
SAE technical papers on CD-ROM/SAE technical paper series
Acoustic Wave Resonator Technologies
article

Reduced Order Model for Viscosity and Mass Density Sensing by A U-Shaped Wire

Zhaoying Zhang, Jianguo Yang, Yajuan Zhao, Baoen Shan, Yitao Shen, Dehong Wu
article en

Abstract

<div class="section abstract"><div class="htmlview paragraph">This paper focuses on the basic principle of measuring viscosity and density with U-shaped tungsten wire sensor, and develops a model for measuring liquid viscosity and density with the help of oscillating ball model. Firstly, the working mechanism of the wire resonator is deeply analyzed. Then, by reducing the order of the fluid dynamic function, a simplified model is established for measuring the viscosity and density of liquid with U-shaped tungsten resonator. The experimental results show that the maximum error of viscosity is 7.22% and the average error is 2.81% when the viscosity ranges from 4.526mPa.s to 62.01mPa.s. In the range of 0.8486g/cm<sup>3</sup> to 0.8711g/cm<sup>3</sup>, the maximum density error is 7.00% and the average density error is 1.89%. In summary, the simplified model proposed in this paper can accurately measure the viscosity and density of liquids.</div></div>

SAE technical papers on CD-ROM/SAE technical paper seriesVol. 1
Harbin Institute of Technology (CN), Zhengzhou University (CN)
Openalex Percentile: Top 94%
Acoustic Wave Resonator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.