Control Trajectory Optimization of Electric Vehicle Heat Pump-Based Cabin Heating System

<div class="section abstract"><div class="htmlview paragraph">Optimal control of battery electric vehicle thermal management systems is essential for maximizi ng the driving range in extreme weather conditions. Vehicles equipped with advanced heating, ventilation and air-conditioning (HVAC) systems based on heat pumps with secondary coolant loops are more challenging to control due to actuator redundancy and increased thermal inertia. This paper presents the dynamic programming (DP)-based offline control trajectory optimization of heat pump-based HVAC aimed at maximizing thermal comfort and energy efficiency. Besides deriving benchmark results, the goal of trajectory optimization is to gain insights for practical hierarchical control strategy modifications to further improve real-time controllers’ performance. DP optimizes cabin inlet air temperature and flow rate to set the trade-off between thermal comfort and energy efficiency while considering the nonlinear dynamics and operating limits of HVAC system in addition to typically considered cabin thermal dynamics. Detailed Dymola-based HVAC system and cabin models are used to parameterize low-order models for control trajectory optimization. Additionally, nonlinear regression models for HVAC power consumption and the Predicted Mean Vote thermal comfort index are developed to construct the optimization cost function. Repeating the optimization for multiple cost function settings yields the Pareto optimal frontiers expressed in terms of aggregated thermal comfort index and energy consumption. Dymola simulation results confirm that incorporating DP-derived insights into a hierarchical control strategy leads to significant improvements in both thermal comfort and energy efficiency compared to baseline hierarchical control strategy.</div></div>

Authors

Institutions

Publication Details

Journal
SAE technical papers on CD-ROM/SAE technical paper series
Published
2025-03-31
DOI
https://doi.org/10.4271/2025-01-8144
Citations
1
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Control Trajectory Optimization of Electric Vehicle Heat Pump-Based Cabin Heating System

Ivan Cvok, Joško Deur
1 citations
SAE technical papers on CD-ROM/SAE technical paper series
Refrigeration and Air Conditioning Technologies
0.71
article

Control Trajectory Optimization of Electric Vehicle Heat Pump-Based Cabin Heating System

Ivan Cvok, Joško Deur
article en
1 citations

Abstract

<div class="section abstract"><div class="htmlview paragraph">Optimal control of battery electric vehicle thermal management systems is essential for maximizi ng the driving range in extreme weather conditions. Vehicles equipped with advanced heating, ventilation and air-conditioning (HVAC) systems based on heat pumps with secondary coolant loops are more challenging to control due to actuator redundancy and increased thermal inertia. This paper presents the dynamic programming (DP)-based offline control trajectory optimization of heat pump-based HVAC aimed at maximizing thermal comfort and energy efficiency. Besides deriving benchmark results, the goal of trajectory optimization is to gain insights for practical hierarchical control strategy modifications to further improve real-time controllers’ performance. DP optimizes cabin inlet air temperature and flow rate to set the trade-off between thermal comfort and energy efficiency while considering the nonlinear dynamics and operating limits of HVAC system in addition to typically considered cabin thermal dynamics. Detailed Dymola-based HVAC system and cabin models are used to parameterize low-order models for control trajectory optimization. Additionally, nonlinear regression models for HVAC power consumption and the Predicted Mean Vote thermal comfort index are developed to construct the optimization cost function. Repeating the optimization for multiple cost function settings yields the Pareto optimal frontiers expressed in terms of aggregated thermal comfort index and energy consumption. Dymola simulation results confirm that incorporating DP-derived insights into a hierarchical control strategy leads to significant improvements in both thermal comfort and energy efficiency compared to baseline hierarchical control strategy.</div></div>

SAE technical papers on CD-ROM/SAE technical paper seriesVol. 1
University of Zagreb (HR)
Openalex Percentile: Top 34%
Refrigeration and Air Conditioning Technologies
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.