A novel rhodamine 6G-based chemosensor for Fe3+ detection in water samples and cellular imaging

A new Schiff base rhodamine 6G-indole-conjugated (RIC) probe with amine groups was synthesized for the highly sensitive and selective detection of Fe 3+ ions. RIC showed selectivity for Fe 3+ with minimal interference from 14 other metal ions. The detection limit was 40 nM. Density functional theory (DFT) was used to predict the orbital electron distribution and molecular geometry of the RIC-Fe 3+ complex. Moreover, confocal laser scanning microscopy was employed to confirm the effectiveness of RIC for detecting Fe 3+ in living cells. Additionally, RIC proved effective in detecting Fe 3+ in aqueous samples, with favorable relative recovery and standard deviations, thus offering a new method for Fe 3+ detection in practical applications. Graphical abstract A new rhodamine-indole conjugated (RIC) probe was designed and synthesized, and used for highly the sensitive and selectivedetection of Fe 3+ ions via fluorimetry.

Authors

Institutions

Publication Details

Journal
Results in Chemistry
Published
2025-03-31
DOI
https://doi.org/10.1016/j.rechem.2025.102228
Citations
2
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
1.51
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel rhodamine 6G-based chemosensor for Fe3+ detection in water samples and cellular imaging

Xiaoniu Yang, Bao-Long Hou, Wenyu Li, Cuiling Wang et al.
2 citations
Results in Chemistry
Molecular Sensors and Ion Detection
1.51
article

A novel rhodamine 6G-based chemosensor for Fe3+ detection in water samples and cellular imaging

Xiaoniu Yang, Bao-Long Hou, Wenyu Li, Cuiling Wang, Jianli Liu, Ruirui Feng
article en
2 citations

Abstract

A new Schiff base rhodamine 6G-indole-conjugated (RIC) probe with amine groups was synthesized for the highly sensitive and selective detection of Fe 3+ ions. RIC showed selectivity for Fe 3+ with minimal interference from 14 other metal ions. The detection limit was 40 nM. Density functional theory (DFT) was used to predict the orbital electron distribution and molecular geometry of the RIC-Fe 3+ complex. Moreover, confocal laser scanning microscopy was employed to confirm the effectiveness of RIC for detecting Fe 3+ in living cells. Additionally, RIC proved effective in detecting Fe 3+ in aqueous samples, with favorable relative recovery and standard deviations, thus offering a new method for Fe 3+ detection in practical applications. Graphical abstract A new rhodamine-indole conjugated (RIC) probe was designed and synthesized, and used for highly the sensitive and selectivedetection of Fe 3+ ions via fluorimetry.

Results in ChemistryVol. 15
Ministry of Education of the People's Republic of China (CN), Xi'an Peihua University (CN), Shaanxi University of Chinese Medicine (CN)
Clean water and sanitation
Openalex Percentile: Top 20%
Molecular Sensors and Ion Detection
1.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A novel rhodamine 6G-based chemosensor for Fe3+ detection in water samples and cellular imaging — Xiaoniu Yang, Bao-Long Hou, et al. · Results in Chemistry (2025) | TGRS Research Map | TGRS