Performance Analysis of Commercial Vehicle Engine Cooling Fan Based on Fluid-Structure Interaction Method

<div class="section abstract"><div class="htmlview paragraph">When the cooling fan of the commercial vehicle engine is working, there is a strong fluid-structure interaction (FSI) between the airflow and the blades. If the effect of this interaction is not considered, significant errors may be caused in the prediction of fan performance. To analyze the effect of FSI on the aerodynamic and structural performance of the cooling fan, calculation models with and without considering FSI were established. The pressure and efficiency of the cooling fan were calculated using three methods: the Multiple Reference Frame (MRF) method, the Sliding Mesh (SM) method, and the bidirectional FSI method. These results were then compared with test data. Based on the FSI method, the aerodynamic and structural performance of the fan at different flow rates, rotational speeds and temperatures were calculated, and compared with results if FSI is ignored. The effect of flow rate, rotational speed and temperature on the fan performance was analyzed. The comparison and analysis results show that: (1) The calculation results of the SM method are generally more accurate than those of the MRF method and the FSI method, with the FSI method being more accurate than the MRF method, especially at high flow points; (2) If fluid-structure interaction is considered, stress and deformation of the blades are smaller compared to the case without FSI; (3) Within the working range, temperature has a significant effect on structural performance but a small effect on aerodynamic performance; (4) Due to the fixed circular shroud at the blade tip, deformation remains minimal, and aerodynamic performance is not significantly affected at operational speeds.</div></div>

Authors

Institutions

Publication Details

Journal
SAE technical papers on CD-ROM/SAE technical paper series
Published
2025-03-31
DOI
https://doi.org/10.4271/2025-01-8641
Primary Topic
Aerodynamics and Fluid Dynamics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Analysis of Commercial Vehicle Engine Cooling Fan Based on Fluid-Structure Interaction Method

Zhihong Yin, Hui Yu, Rex Ying, Yaolong Duan et al.
SAE technical papers on CD-ROM/SAE technical paper series
Aerodynamics and Fluid Dynamics Research
article

Performance Analysis of Commercial Vehicle Engine Cooling Fan Based on Fluid-Structure Interaction Method

Zhihong Yin, Hui Yu, Rex Ying, Yaolong Duan, Xinling Wang, Wen-Bin Shangguan
article en

Abstract

<div class="section abstract"><div class="htmlview paragraph">When the cooling fan of the commercial vehicle engine is working, there is a strong fluid-structure interaction (FSI) between the airflow and the blades. If the effect of this interaction is not considered, significant errors may be caused in the prediction of fan performance. To analyze the effect of FSI on the aerodynamic and structural performance of the cooling fan, calculation models with and without considering FSI were established. The pressure and efficiency of the cooling fan were calculated using three methods: the Multiple Reference Frame (MRF) method, the Sliding Mesh (SM) method, and the bidirectional FSI method. These results were then compared with test data. Based on the FSI method, the aerodynamic and structural performance of the fan at different flow rates, rotational speeds and temperatures were calculated, and compared with results if FSI is ignored. The effect of flow rate, rotational speed and temperature on the fan performance was analyzed. The comparison and analysis results show that: (1) The calculation results of the SM method are generally more accurate than those of the MRF method and the FSI method, with the FSI method being more accurate than the MRF method, especially at high flow points; (2) If fluid-structure interaction is considered, stress and deformation of the blades are smaller compared to the case without FSI; (3) Within the working range, temperature has a significant effect on structural performance but a small effect on aerodynamic performance; (4) Due to the fixed circular shroud at the blade tip, deformation remains minimal, and aerodynamic performance is not significantly affected at operational speeds.</div></div>

SAE technical papers on CD-ROM/SAE technical paper seriesVol. 1
South China University of Technology (CN)
Openalex Percentile: Top 92%
Aerodynamics and Fluid Dynamics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.