Electrochemical Evaluation of Carbon Steel and Galvanized Steel Rebar Embedded in Sustainable Ternary Blended Concrete by EIS

Abstract. This research investigated the effect of supplementary cementitious materials (SCMs) on the electrochemical corrosion behavior of carbon steel (CS) and galvanized steel (GS) rebars embedded in ternary blended systems by electrochemical impedance spectroscopy (EIS) measurements. These steel-concrete systems were prepared with a water/cement ratio of 0.45 and partial substitutions of the Ordinary Portland Cement (OPC) by sugarcane bagasse ash (SCBA) and fly ash (FA). The OPC and SCMs were characterized by scanning electronic microscopy (SEM) and X-ray diffraction (XRD) analysis. The EIS results indicated that the SCMs contributed to the electrochemical behavior of ternary steel-concrete at an early stage of the hydration process. The higher values of resistance (Rfilm) were obtained in the concentration of 30 % substitution. This fact was attributed to the oxygen decrease on the metal surface, which was confirmed by the decrease of the electrochemical double layer capacitance (Cdl) value with respect to the reference specimen. Resumen. Esta investigación estudió el efecto de materiales cementantes suplementarios (SCM) sobre el comportamiento de la corrosión electroquímica de barras de refuerzo de acero al carbono y acero galvanizado embebidas en sistemas de concreto ternarios mediante mediciones de Espectroscopía de Impedancia Electroquímica (EIS). Estos sistemas acero-concreto se prepararon con una relación agua/cemento de 0.45 y sustituciones parciales del Cemento Portland Ordinario (OPC) por ceniza de bagazo de caña (SCBA) y cenizas volantes (FA). El OPC y los SCM se caracterizaron mediante análisis de microscopía electrónica de barrido (SEM) y difracción de rayos X (DRX). Los resultados del EIS indicaron que los SCM contribuyeron al comportamiento electroquímico del acero-hormigón ternario en una etapa temprana del proceso de hidratación. Los mayores valores de resistencia (Rfilm) se obtuvieron en la concentración del 30 % de sustitución. Este hecho se atribuyó a la disminución de oxígeno en la superficie del metal, lo que fue confirmado por la disminución del valor de capacitancia electroquímica de doble capa (Cdl) con respecto a la muestra de referencia.

Authors

Institutions

Publication Details

Journal
Journal of the Mexican Chemical Society
Published
2025-04-01
DOI
https://doi.org/10.29356/jmcs.v69i2.2178
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Evaluation of Carbon Steel and Galvanized Steel Rebar Embedded in Sustainable Ternary Blended Concrete by EIS

Andrés Carmona-Hernández, Ricardo Orozco-Cruz, Dulce Cruz-Moreno, G. Fajardo-San-Miguel et al.
1 links
Journal of the Mexican Chemical Society
Concrete Corrosion and Durability
article

Electrochemical Evaluation of Carbon Steel and Galvanized Steel Rebar Embedded in Sustainable Ternary Blended Concrete by EIS

Andrés Carmona-Hernández, Ricardo Orozco-Cruz, Dulce Cruz-Moreno, G. Fajardo-San-Miguel, Ricardo Galván-Martínez, Aldo Emelio Landa-Gomez
article en

Abstract

Abstract. This research investigated the effect of supplementary cementitious materials (SCMs) on the electrochemical corrosion behavior of carbon steel (CS) and galvanized steel (GS) rebars embedded in ternary blended systems by electrochemical impedance spectroscopy (EIS) measurements. These steel-concrete systems were prepared with a water/cement ratio of 0.45 and partial substitutions of the Ordinary Portland Cement (OPC) by sugarcane bagasse ash (SCBA) and fly ash (FA). The OPC and SCMs were characterized by scanning electronic microscopy (SEM) and X-ray diffraction (XRD) analysis. The EIS results indicated that the SCMs contributed to the electrochemical behavior of ternary steel-concrete at an early stage of the hydration process. The higher values of resistance (Rfilm) were obtained in the concentration of 30 % substitution. This fact was attributed to the oxygen decrease on the metal surface, which was confirmed by the decrease of the electrochemical double layer capacitance (Cdl) value with respect to the reference specimen. Resumen. Esta investigación estudió el efecto de materiales cementantes suplementarios (SCM) sobre el comportamiento de la corrosión electroquímica de barras de refuerzo de acero al carbono y acero galvanizado embebidas en sistemas de concreto ternarios mediante mediciones de Espectroscopía de Impedancia Electroquímica (EIS). Estos sistemas acero-concreto se prepararon con una relación agua/cemento de 0.45 y sustituciones parciales del Cemento Portland Ordinario (OPC) por ceniza de bagazo de caña (SCBA) y cenizas volantes (FA). El OPC y los SCM se caracterizaron mediante análisis de microscopía electrónica de barrido (SEM) y difracción de rayos X (DRX). Los resultados del EIS indicaron que los SCM contribuyeron al comportamiento electroquímico del acero-hormigón ternario en una etapa temprana del proceso de hidratación. Los mayores valores de resistencia (Rfilm) se obtuvieron en la concentración del 30 % de sustitución. Este hecho se atribuyó a la disminución de oxígeno en la superficie del metal, lo que fue confirmado por la disminución del valor de capacitancia electroquímica de doble capa (Cdl) con respecto a la muestra de referencia.

Journal of the Mexican Chemical Society
Universidad Veracruzana (MX), Universidad Autónoma de Nuevo León (MX)
Openalex Percentile: Top 94%
Concrete Corrosion and Durability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.