Deformable image registration with multi-level self-cross transformer architecture for the combined radiotherapy treatment of cervical cancer patients

The combined radiotherapy treatment is critical for the cervical cancer. This study aims to present an accurate deformable image registration method, which is critical to estimate the combined dose of External Beam Radiotherapy (EBRT) and Intracavitary Brachytherapy (ICBT). We introduce an enhanced Transformer based deformable image registration method to register the CT scans of EBRT and ICBT, which is characterized by a novel multi-level self-cross Transformer architecture based registration network (SCT-Net). In order to quantitatively evaluate the registration performance, the average dice similarity coefficient (DSC) and Hausdorff distance (HD) of the rectum and bladder between EBRT and ICBT after deformable image registration are computed with 80 cervical cancer patients. Without the registration between CT scans of EBRT and the last ICBT, the mean DSC values for bladder and rectum are 0.65 and 0.43, and the HD95 values for bladder and rectum are 6.1 and 6.6, respectively. After the registration, the mean DSC values of SCT-Net, XMorpher, VoxelMorph for bladder are 0.76, 0.74 and 0.70, respectively. Meanwhile, the mean DSC values of SCT-Net, XMorpher, VoxelMorph for rectum are 0.54, 0.52 and 0.49, respectively. In addition, the mean HD95 values of SCT-Net, XMorpher, VoxelMorph for bladder are 4.4, 4.8 and 5.2, respectively. Moreover, the mean HD95 values of SCT-Net, XMorpher, VoxelMorph for rectum are 5.9, 6.1 and 6.3, respectively. Visualized registration results further demonstrate the superiority of the proposed SCT-Net. These experimental results effectively demonstrate the superiority of the proposed SCT-Net for the deformable registration between the EBRT and ICBT, which is critical for the accumulative dose calculation of combined radiotherapy treatment.

Authors

Institutions

Publication Details

Journal
Journal of Radiation Research and Applied Sciences
Published
2025-03-31
DOI
https://doi.org/10.1016/j.jrras.2025.101454
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deformable image registration with multi-level self-cross transformer architecture for the combined radiotherapy treatment of cervical cancer patients

Linzhen Lan, Chuanshu Cai, Feibao Guo, Simin Lin et al.
Journal of Radiation Research and Applied Sciences
Advanced Radiotherapy Techniques
article

Deformable image registration with multi-level self-cross transformer architecture for the combined radiotherapy treatment of cervical cancer patients

Linzhen Lan, Chuanshu Cai, Feibao Guo, Simin Lin, Xuanyu Liu, Shaobin Wang, Qi Chen, Shuying Chen, Qing He, Yi Guo
article en

Abstract

The combined radiotherapy treatment is critical for the cervical cancer. This study aims to present an accurate deformable image registration method, which is critical to estimate the combined dose of External Beam Radiotherapy (EBRT) and Intracavitary Brachytherapy (ICBT). We introduce an enhanced Transformer based deformable image registration method to register the CT scans of EBRT and ICBT, which is characterized by a novel multi-level self-cross Transformer architecture based registration network (SCT-Net). In order to quantitatively evaluate the registration performance, the average dice similarity coefficient (DSC) and Hausdorff distance (HD) of the rectum and bladder between EBRT and ICBT after deformable image registration are computed with 80 cervical cancer patients. Without the registration between CT scans of EBRT and the last ICBT, the mean DSC values for bladder and rectum are 0.65 and 0.43, and the HD95 values for bladder and rectum are 6.1 and 6.6, respectively. After the registration, the mean DSC values of SCT-Net, XMorpher, VoxelMorph for bladder are 0.76, 0.74 and 0.70, respectively. Meanwhile, the mean DSC values of SCT-Net, XMorpher, VoxelMorph for rectum are 0.54, 0.52 and 0.49, respectively. In addition, the mean HD95 values of SCT-Net, XMorpher, VoxelMorph for bladder are 4.4, 4.8 and 5.2, respectively. Moreover, the mean HD95 values of SCT-Net, XMorpher, VoxelMorph for rectum are 5.9, 6.1 and 6.3, respectively. Visualized registration results further demonstrate the superiority of the proposed SCT-Net. These experimental results effectively demonstrate the superiority of the proposed SCT-Net for the deformable registration between the EBRT and ICBT, which is critical for the accumulative dose calculation of combined radiotherapy treatment.

Journal of Radiation Research and Applied SciencesVol. 18(2)
Fujian Medical University (CN), First Affiliated Hospital of Fujian Medical University (CN), Tsinghua University (CN)
Good health and well-being
Openalex Percentile: Top 92%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.